Maintenance
5-36
HPR130XD Auto Gas –
806330
c
oolant flow troubleshooting chart
Coolant error (093) or (060)
Go to “pump/motor
troubleshooting”
Order a replacement check valve or your coolant will drain out at
each consumable change
There is a kink in the return hose to
the power supply. If there is not a kink,
replace the hose.
Go to “steps to take before testing” on the next page
Go to test 1
Go to test 2
Go to test 7
Replace the flow switch
Go to test 3
Replace the torch if the flow shown
on the CNC is
> 0.9 gpm
Go to test 4
Go to test 5
Check your power supply outlet hose for kinks. If there are no kinks, replace the hose set between the power supply and
the high frequency console.
There is a kink or clog between the
high frequency console and the
power supply. If there is not a kink,
replace the leads.
There is a kink in the leads between the high frequency console and the
torch. If there is not a kink,
replace the leads.
Go to test 6
Replace the pump, and inspect
the shaft for damage
No flow
Flow
rate
from bucket test
> 0.9 gpm
Flow
rate from flow tube > 0.8 gpm
Flow
rate from flow tube < 0.8 gpm
Flow
rate from
c
N
c
> 0.8 gpm
Flow
rate from
c
N
c
< 0.8 gpm
Flow
rate from
c
N
c
< 0.9 gpm
Flow rate
from bucket test
< 0.9 gpm
Flow rate
from bucket test
< 0.9 gpm
Flow rate
from bucket test
> 0.9 gpm
Flow rate
from bucket test
< 0.9 gpm
Flow rate
from bucket test
> 0.9 gpm
Flow rate
from bucket test
< 0.9 gpm
Flow rate
from bucket test
> 0.9 gpm
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...