Maintenance
HPR130XD Auto Gas –
806330
5-27
Error code troubleshooting – error code 181, 182, 298, and 383
Error code
number
Name
Description
corrective action
181
Metering
console CAN
time-out
Auto gas
only
The power supply did not
receive a CAN message
from the metering console
within 1 second.
1. Verify that the power supply-to-metering console
CONTROL and POWER cables are not damaged and
are properly connected to PCB3, and the rear of the
metering console.
2. Verify that D17 (+5 VDC) and D18 (+3.3 VDC) are
illuminated on PCB2 inside the metering console.
These LEDs indicate power to PCB2.
Also verify that
D26 (CAN – RX) and D27 (CAN – TX) are illuminated on
PCB2 inside the metering console. These LEDs indicate
communication between the metering console and the
power supply.
3. If power is present at PCB2 and PCB3 and both metering
console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.
4. Verify that the gas console control PCB and power
distribution PCBs are securely mounted to the chassis
at all four corners.
182
Secondary
power supply
time-out
HPR800XD
only
The secondary power
supply fails before
transmitting the error to
the primary power supply.
1. The primary power supply to secondary power supply
CAN communication cable was disconnected after
power-up.
2. The cable has electrical interference (noise) or the cable
shielding has been compromised.
298
Secondary
power supply
phase loss at
initialization
HPR800XD
only
The system detected
incoming line voltage
during power-up, before
the contactor was
energized.
1. Verify phase-to-phase voltage to power supply.
2. Disconnect power to power supply, remove cover on
contactor and inspect contacts for excessive wear.
3. Inspect power cord, contactor, and input to chopper for
loose connections.
4. Inspect phase loss fuses on Power Distribution board.
Replace board if fuses are blown.
5. Perform phase loss test (see
Maintenance
section).
383
No ramp-up
message
HPR800XD
only
The secondary power
supply is ready to provide
current output but does
not receive the control
signal from the primary
power supply.
1 Turn off the power to the system and then turn on the
power again.
2. The cable has electrical interference (noise) or the cable
shielding has been compromised.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...