Appendix D
d-4
HT4001 Instruction Manual
4.
Connect the power leads to the U, V, and W terminals of TB5. Ensure that all
connections are tight to avoid excessive heating.
5.
Connect the ground lead to terminal marked with the ground symbol at TB5 (see
Figure d-3).
Figure d-3 Power Cable Connections to TB5
TB5 (029165)
Line Disconnect Switch
Connecting the power cable to the line disconnect switch must conform to national or
local electrical codes. This work should be performed only by qualified, licensed
personnel. See
Power Requirements and Line Disconnect Switch on pages 3-4 and
3-5.
WARNING
The neon light attached to the terminal box will turn ON as soon as the line disconnect
switch is ON. This indicator is a warning that there is line voltage at the terminal block
even if the circuit breaker on the HT4001 power supply is OFF. As a common safety
practice, ALWAYS verify that the line disconnect switch is in the OFF position before
installing, disconnecting or servicing in this area.