All Echion-model pumps
Environmental conditions
Hydraulic fluid
A laboratory analysis of hydraulic fluid can tell you if replacement is recommended.
The maximum contamination from particulates that is permitted is 19/17/14 when tested according
to ISO 4406. The maximum recommended contamination from water is 300 ppm when tested
according to ASTM D6304c-04. If it is not practical to analyze a sample of your hydraulic fluid,
Hypertherm recommends replacing it every 3,000 hours.
Glycol can be added to the cooling circuit to prevent freezing, but glycol is less efficient for
cooling than water.
Hypertherm recommends using a solution of not more than 25% glycol in chillers for this
system.
Ambient air temperature
4°C to 35°C (40°F to 95°F)
Relative humidity
Noncondensing
95%
Storage temperature
Water not drained
2°C to 55°C (35°F to 131°F)
Domestic pumps ship from the factory with AW 32 hydraulic fluid.
Type
Antiwear (AW) mineral oil or synthetic hydraulic fluid, ISO viscosity
grade (VG) 32 or 46
Hydraulic fluid tank capacity
120 L (32 gallons)
Maximum pressure
Set at the factory
217 bar (21,700 kPa / 3,150 psi)
Operation temperature
46°C to 54°C (115°F to 130°F)
Summary of Contents for Echion
Page 1: ...Echion Operator Manual 810770 REVISION 3 ENGLISH ...
Page 11: ...Echion Operator Manual 810770 SC 11 Warranty Warranty ...
Page 17: ...Echion Operator Manual 810770 SC 17 Environmental stewardship Environmental stewardship ...
Page 28: ...Safety SC 28 810770 Operator Manual Echion Safety ...
Page 29: ...Echion Operator Manual 810770 SC 29 Symbols and marks Symbols and marks ...
Page 34: ...Symbols and marks SC 34 810770 Operator Manual Echion Symbols and marks ...
Page 36: ...Optional equipment 1 36 810770 Operator Manual Echion Optional equipment ...
Page 110: ...Parts lists 4 110 810770 Operator Manual Echion Parts lists ...
Page 172: ...Installation 7 172 810770 Operator Manual Echion Installation ...
Page 176: ...Touchscreen maps 9 176 810770 Operator Manual Echion Touchscreen maps ...
Page 178: ...Touchscreen maps 9 178 810770 Operator Manual Echion ...
Page 180: ...Touchscreen maps 9 180 810770 Operator Manual Echion ...
Page 182: ...Touchscreen maps 9 182 810770 Operator Manual Echion ...
Page 184: ...Touchscreen maps 9 184 810770 Operator Manual Echion ...
Page 186: ...Touchscreen maps 9 186 810770 Operator Manual Echion ...
Page 188: ...Touchscreen maps 9 188 810770 Operator Manual Echion ...
Page 190: ...Technical drawings 10 190 810770 Operator Manual Echion Technical drawings ...
Page 191: ...Technical drawings 10 Echion Operator Manual 810770 191 SCHEM ECHION HYD WTR ...
Page 192: ...Technical drawings 10 192 810770 Operator Manual Echion ...
Page 194: ......