9.4.5 Cleaning the vent hole on the
pipe elbow
»
Check the small opening on the top
of the pipe elbow for dirt.
»
Remove any dirt, e.g. with a small
screwdriver.
»
Follow the handling instructions in
the section
Leakage tes
t.
The vent hole should be checked for free cir-
culation during every maintenance. A blocked
vent hole has a negative effect on the drain-
age process (see also chapter "Trouble
shooting" in the manual of the control).
9.4.6 Reinstallation of the steam cyl-
inder
»
Place the cylinder vertically in cylin-
der base.
»
Reconnect connector halves.
The colour of the respective connection cable
must match the colour of the respective elec-
trode hand nut.
»
Check all cabling screw terminals
and plugs for tight seating. Plugs
must sit on their respective contacts
as far as they will go.
»
Check electrode plugs for corro-
sion. Replace, if stained.
Risk of functional disruption!
Risk of material damage!
Loose cable connections may result in
increased transition resistance and contact
area overheating.
»
Check all cabling terminals and
plugs for tight seating. Plugs must sit
on their respective contacts as far as
they will go.
»
Check heater element wiring for
damaged insulation
»
Reattach Super Flush solenoid hose
(if applicable) to steam cylinder bot-
tom stub.
»
Attach steam hose adapter to cylin-
der.
»
Follow the handling instructions in
the section
Leakage tes
t.
Please note
Please note
NOTICE