Page 34
9.4 Removing and cleaning the
steam cylinder
Risk of eye injuries!
The clips that fix the steam cylinder halves
have sharp edges and can jump off during dis-
mantling.
Eye injuries possible.
Wear proper PPE (Personal Protection Equip-
ment)!
Steam cylinder removal
»
Remove unit housing cover
»
Remove water sensor hose from
cylinder top.
»
Remove SuperFlush solenoid hose
from cylinder bottom (if applicable).
»
Remove steam hose from steam
hose adapter.
If the steam hose is not to be disconnected,
the steam hose adapter with the steam hose
still attached may be detached from the
steamcylinder as shown in the next figure.
CAUTION
!
Set control
switch to „II“ posi-
tion for residual
water draining
When cylinder is empty, set
control switch to „0“ position
Disconnect unit from power supply
and secure against reconnection
Verify safe isolation
Current clamp
Disconect water supply
Wait 10 mins. Then check cylinder
temperature by cautious approximati-
on with hand (do not touch!)