Page 33
6. Water Installation
Warning:
For installation, note the following:
•
Have all work performed by a professional.
•
Disconnect power supply prior to installation.
•
Obey regulations of local public utilities.
•
Install a backflow preventer.
•
The water supply temperature may not exceed 60 °C.
•
Flushed-out water must be able to drain freely.
•
The water supply line must have a minimum diameter of
DN 12 (3/8").
•
If (chemical) additives are present in the humidification
water, health risks and/or impaired unit operation cannot
be ruled out. Use of additives is not advised unless specif-
ically recommended by the unit manufacturer.
•
When employing demineralized water or purified conden-
sate, do not use copper or brass in the supply or drain
lines of the HeaterLine unit. These materials can be cor-
roded by demineralized water or purified condensate.
Instead, use stainless steel or temperature-resistant plas-
tic pipes.
•
Water installation pressure: 100 x 10
3
bis 100 x 10
4
Pascal
(1 bis 10 bar).
6.1 Water Quality
The DemiLine Type steam humidifier is designed for use with:
•
fully demineralized water / cleaned condensate