14.
Terminal Assignments on the Unit Con-
nector Strip and Wiring Diagram Legend
Unit Connector Strip:
Terminals
Assignment
1 / 2
Remote Switch / Safety Interlock
6 / 7
Temperature Sensor
8 / 9 / 13
Essence Injector max. 70 W / 24 V / 3,15 A
10 / 11
Exhaust Fan max. 40 W / 24 V / 1,6 A
10 / 12
Supply Fan max. 40 W / 24 V / 1,6 A
14 / 15
Light max. 40 W / 24 V / 1,6 A
17 / 18 / 19
Essence Injector max. 70 W / 230 V / 300 mA
20 / 21
Exhaust Fan max. 40 W / 230 V / 175 mA
20 / 22
Supply Fan max. 40 W / 230 V / 175 mA
44 / 45
Light 40 W / 230 V / 175 mA
Wiring Diagram Legend:
Designation
Specification
B1
Max.-Water Level Electrode
B3
Transducer
F1
Fuse Control 1,6 A
F2
Fuse Transformer 5 A
F3
Essence Injector Fuse 2,5 A
F4
Exhaust Fan Fuse 1,6 A
F5
Supply Fan Fuse 1,6 A
F6
Light Fuse 1,6 A
K1
Main Contactor
L1 - L3
Main Terminals
M1
Blow-Down Pump
N
Neutral
PE
Grounding Terminal
S1
Control Switch ON (I) / OFF (0), pumping (II)
X1
Connector Strip
Y1
Solenoid Valve
Y2
SUPER FLUSH (optional)