SPA
Page 14
4.
User Mode - Communication with the Con-
trol (Comfort-DS/ Comfort Plus-DS)
After switching on the steam humidifier, the user is placed in user
mode.
This mode includes the indicators and controls needed to modify the
following parameters:
-
Temperature Set Value
°C - (Key )
-
Steam Bath Fan Function F
- (Key )*
-
Essence Delivery Function E
- (Key )*
-
Cabin Light Function
L
- (Key )*
*: no function for steam generators type C01 and C02
The active steam bath temperature is always simultaneously dis-
played.
For safety reasons, modifications to steam bath parameters in user
mode are temporary, i.e. they are lost when the steam humidifier is
switched off. Upon restart the unit operates with the previously entered
parameter settings.
Permanent parameter modifications are done in operating mode, also
see section “Operating Mode - Advanced Communication with the
Control”.
4.1
Changing Steam Bath Parameters in User Mode
Risk of scalding due to excessively set steam bath temperature!
Any changes in setting must be well considered and performed in
small steps only.
4.1.1
Modifying the Temperature Set Value (G2)
In user mode, the temperature may be modified in increments of
0.5°C.When the system is switched off, all changes made are lost.
Example:
To reduce the desired temperature value from 45°C to
42°C.
Switch on steam generator. The display indicates the type of operation-
and the active cabin temperature.
»
Press
once. The programmed temperature value
appears on the display.
»
Hold down
until the temperature value 42°C appears
on the display.
Please note
Please note
Steam Bath
45 °C
Menu