START-UP OF THE SERVICE MEASURING KIT
HySense
®
CX 197
14
ENG
•
For the pressure connection, use the hose line with the check valve on one
side. First connect the simple side (without check valve) to the CX 197 on
the input side (point
A
•
Then finally, you can connect this hose line with the check valve to the
pressure connection of the hydraulic system
The CX 197 does not have its own pump, which is why it is installed in the
pressure line. The symbols P and T with an arrow are engraved on the front
side of the CX 197. The arrows on the CX 197 indicate the flow direction of the
medium. The P symbol stands for pressure and the T for the tank side (Figure 3
or Figure 4). The warning on the front of the CX 197 (Figure 4) symbolizes the
correct connection sequence with the maximum pressures that may not be
exceeded.
Figure 4: Printing on the CX197 (pictograms)
4.1.1 Installation in the pressure line
An installation of the CX 197 is recommended in a pressure line to the Figure 5
left. Here, it can be connected directly to a Minimess
®
test point with the
included lines. The return can be connected directly to a tank line on the system
(heed connection sequence, see Chapter 4.1).
Alternatively, test points can be selected for which there is a sufficient pressure
difference for a suitable flow (Figure 5 right).
Warning
Incorrect sequence during connection
•
Sensors can be damaged
•
Oil can escape