I
INTRODUCTION
MODEL NUMBERS AND SYSTEM CONFIGURATIONS
Table 1
GUIDE IS APPLICABLE TO HYDROTECH
®
REVERSE OSMOSIS DRINKING WATER TREATMENT SYSTEMS AS SPECIFIED IN THIS TABLE
Select System Code and Output Code to Determine Model Number
System Code
12301
12302
12303
12304
Output (GPD)*
9
25
50
75
9
25
50
75
9
25
50
75
9
25
50
75
Output Code
03
02
01
00
00
01
02
03
00
01
02
03
00
01
02
03
Vessels
3
4
4
4
Monitor
None
None
Pushbutton Smartap
®
Faucet Smartap
®
Sediment Filter
None
String Wound Polypropylene
String Wound Polypropylene
String Wound Polypropylene
Pre-Filter
Dual-Purpose
Activated Carbon
Activated Carbon
Activated Carbon
Membrane
Thin Film Composite
Post Filter
Activated Carbon
* Manufacturer’s Specification with inlet conditions of 372 kPa (60 psig), 25
°
C (77
°
F), going to atmosphere.
CONDITIONS FOR USE
THIN FILM COMPOSITE MEMBRANE
Source Water Supply Profile
Chemical Parameters
Max mg/L
Community/Private
Chlorinated/Non-Chlorinated
Hardness (CaCO
3
)
<350
Feed Water Pressure
1
242-690 kPa (35-100 psig)
Iron (Fe )
<0.1
Temperature
4°-38° C (40°-100° F)
Manganese (Mn)
<0.05
pH Range
3.0 - 11.0
Hydrogen Sulfide (H
2
S )
0.00
Maximum TDS Level
2000 mg/L
Residual Chlorine (Cl
2
)
<2.0
Turbidity**
<1.0 NTU
Maximum SDI***
<4.0
** Nephelometric Turbidity Unit
*** Silt Density Index: Value stated in SDI units.
NOTE: 1. PRESSURE REGULATOR IS RECOMMENDED FOR FEED WATER PRESSURES EXCEEDING 552 kPa (80 psig).
OPTIONS AND ACCESSORIES
PRODUCT WATER FAUCETS
BOOSTER PUMP
Faucets are available as Air Gap and Non-Air Gap in
Chrome-Plated Metal (EPA and California Proposition 65 Compliant)
or an Air Gap molded Polymer
that is available with or without Light Bar.
A booster pump may be used if system pressure is below 242 kPa (35 psi).
Pump should be placed near RO Module and installed in feed water line just
before it enters Module. Power supplies are available in a variety of voltages.
SMARTAP
®
WATER QUALITY MONITOR
PUSHBUTTON - METAL OR POLYMER FAUCET
Indicator lights located on the module cover report system status.
Pressing a test button located on the manifold cover activates monitor.
FAUCET ACTUATED - POLYMER FAUCET
Indicator lights appearing in a Light Bar report system status. Light Bar is
integrated into body front cover. It connects to electronics inside RO Module
by a length of phone cord routed to terminal on manifold cover.
CONTACT YOUR HYDROTECH DEALER TO PURCHASE REPLACEMENT PARTS AND ACCESSORIES.
TO LOCATE YOUR LOCAL DEALER, CALL HYDROTECH
IN CANADA 877.299.5999
IN THE UNITED STATES 800.354.7867