background image

2

UVB SERIES - SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES

PREPARATION – INSPECT ALL PARTS

NOTE:  

Read Mounting Bracket and System Plumbing 

Installation instructions on Page 1 and all instructions 

on this page before installing system.

NOTE:  

See Page 4 for UVB detailed parts breakdown. Refer 

to the label affixed to the mounting bracket to identify 

filter(s) to be installed with UV module.

CONTROL MODULE INSTALLATION 

CONTROL MODULE INSTALLATION WITH SAFETY ROD FOR 

UVB MODELS WITHOUT THE LOC OPTION

INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM

Check page 20 for pictures of Quartz Sleeve.

CAUTION:   QUARTZ SLEEVE IS VERY FRAGILE!  

For safety, wear a protective glove when handling 

quartz sleeve. Do not touch quartz sleeve or UV 

lamp with bare hands. Fingerprints will reduce the 

effectiveness of the light.

NOTE: 

 

All Items refer to Figure 1.

1. Remove Sump (Item 1) from UV Head (Item 5).

NOTE:

 

 Do not remove protective plastic bag from quartz 

sleeve until so instructed. 

2.  Remove Quartz Sleeve (Item 17) from packing tube. While 

holding middle of quartz sleeve with one hand, slide protective 

bag with other hand to expose open end.

3.  Place a small amount of silicone based “O” ring lubricant on the 

outside of the open end of the quartz sleeve only on the area that 

will engage with the “O” ring.

CAUTION:

   Apply even pressure to push the quartz sleeve into the 

UV head. To avoid breakage, make sure quartz sleeve 

goes in straight by pushing it with a slight twisting 

motion.

4.  Insert quartz sleeve into the UV head. As quartz sleeve passes 

the “O” Ring (Item 15), resistance will be felt. Remove protective 

bag from quartz sleeve.

5.  Remove EPCB™ Carbon Filter (Item 3) and EPCB™ Sleeve 

(Item 24) from sump and set aside.

6. 

 For UVB2 and UVB3 Models only:

 Remove Sump (Item 1) from 

Filter Head (Item 20). Remove Filters (Items 21 and 23) from 

sump and set aside.

7. Disinfect the system (Pages 18-19, Steps 1-7).

INSTALL ULTRAVIOLET LIGHT AND FILTERS

1. Remove Sump (Item 1) from UV Head (Item 5).

NOTE:

 

 Wipe all fingerprints and excessive lubricant from 

quartz sleeve with isopropyl alcohol. 

2.  Install EPCB™ Sleeve (Item 24) into EPCB™ Carbon Filter (Item 

3) as shown in Figure 1.

3.  Insert filter/sleeve assembly into sump as shown in Figure 1 with 

both Filter Gaskets (Item 4) in place.

CAUTION:

   TIGHTEN SUMPS BY HAND ONLY. Do not use tools 

as they will over-tighten and may damage sump. Take 

care not to cut or pinch “O” Rings (Item 2). Use sump 

wrench for removal only.

4.  Being careful not to dislodge quartz sleeve, install sump with filter/

sleeve assembly onto UV head.

5. 

 For UVB2 & UVB3 Models only: 

Remove Sump (Item 1) from 

Filter Head (Item 20). Install Filters (Items 21 and 23) as shown in 

Figure 1. Install sump onto filter head.

CAUTION:   DO NOT INSTALL A DAMAGED LAMP

INSTALL CONTROL MODULE AND UV LAMP

NOTE: 

 Hold UV lamp by ceramic ends only. Do not touch the 

glass. Clean with isopropyl alcohol if necessary.

6.  Remove UV Lamp (Item 16) from packing tube and inspect it for 

damage. If damage is found, contact the dealer for a replacement.

UVB SERIES

UVB Ultraviolet System 

Control Module Box

Ultraviolet Lamp #11 (in packing tube)

Quartz Sleeve #11 (in packing tube)

Mounting Screws (2-4 pieces, varies with model)

Installation Manual and Owners Guide

Sump Wrench #10/20

Figure 1A

 - * UVB-3 model shown

Figure 1B

 - * UVB-3 model shown

Summary of Contents for Aqua Flo ADDON Series

Page 1: ...INSTALLATION MANUAL OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev 07 16...

Page 2: ......

Page 3: ...________________ 8 INSTALL ULTRAVIOLET LIGHT AND FILTERS______________________________________________ 8 9 ACTIVATE SYSTEM___________________________________________________________________ 9 SERVICE...

Page 4: ...and create active sites where pollutants can be collected by adsorption These new sites dramatically increase the total surface area and capacity of each granule WHAT IS ADSORPTION Adsorption is the p...

Page 5: ...quartz sleeve UV Lamp Replacement Lamps must be changed every twelve months While UV lamps rarely burn out they do lose their disinfection power Use only UV UV lamps as they are specifically designed...

Page 6: ...V system to service the sumps and UV lamp without removing the UV system The minimum space is UVB 11 above and below UV20 UVBB 20 above and below UV1 10 above and below ADDON 10 or 20 above by model 4...

Page 7: ...ing Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 Remove EPCB Carbon Filter Item 3 and EPCB Sleeve Item 24 from sump and set aside 6 For UVB2 and UVB3 Models only Remove S...

Page 8: ...outlet If the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 9 above It is norma...

Page 9: ...2800031 15 O Ring Quartz Sleeve Standard 34202021 16 Lamp UV 11 36002017 17 Sleeve Quartz 11 w O Rings 36003034 18 Rod Safety Plunger 22401015 19 Spacer Bushing 10 20 22401016 20 Head Filter 3 4 10 20...

Page 10: ...tion 4 Insert quartz sleeve into the UV head As quartz sleeve passes the O Ring Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 For UV20 2 and UV20 3 Models only Remove Sump...

Page 11: ...the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 8 above It is normal for the...

Page 12: ...1 14 Washer 14 Nylon 32800031 15 O Ring Quartz Sleeve Standard 34202021 16 Lamp UV 20 36002018 17 Sleeve Quartz 20 with O Rings 36003035 18 Rod Safety Plunger 22401015 19 Spacer Bushing 10 20 22401016...

Page 13: ...from quartz sleeve NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 6 For UVBB 2 and UVBB 3 Models only Remove Sump Item 1 from Filter Head Item 20 Remove F...

Page 14: ...When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now...

Page 15: ...trol BB 44302403 11 Screw 6 32 x 3 8 32701063 12 Screw 14 x 1 32701060 13 Screw 5 16 x 1 1 4 32701074 14 Washer 5 16 32800029 15 O Ring Quartz Sleeve BB 34202022 16 Lamp UV 20 36002018 17 Sleeve Quart...

Page 16: ...6 nuts securing corner braces INSTALL UV SYSTEM TO RACK NOTE Items in this section refer to Figure 5 NOTE Figures 5 and 6 provide examples of configurations that may be applied to your UV system These...

Page 17: ...stem Configuration and Component Parts Initial Installation DATE INSTALLED SYSTEM OUTPUT RATING LPM GPM CONFIGURATION SERIES SERIES TO PARALLEL PARALLEL PARALLEL TO SERIES MODULE 1 TYPE UV PART NUMBER...

Page 18: ...r pin socket that is connected to the UV Control Item 11 8 Carefully insert the UV lamp through mounting bracket into the quartz sleeve as far as possible NOTE End of UV lamp will touch bottom of quar...

Page 19: ...rol with Finish Cap 40200080 12 Bushing Spacer 10 SL 22401017 13 Cap Finish c w Control 14 Sleeve Quartz 10 with O Rings 36003033 15 Sleeve Teflon 30120506 16 O Ring Quartz Sleeve UV1 34202020 17 Lamp...

Page 20: ...they will over tighten and may damage sump Take care not to cut or pinch Addon Sump Gasket Item 2 1 For ADDON 1GPM Model Only Remove Collar Item 15 from UV Head Item 5 NOTE Wipe all fingerprints and...

Page 21: ...f UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks If there are leakages in the quick connect fittings check for the O ring pl...

Page 22: ...p 40200080 11 Retainer O Ring Cap Finish c w Control 22401012 12 Sleeve Quartz 10 with O Rings 13 Sleeve Quartz 11 with O Rings 36003034 13A Sleeve Quartz 20 with O Rings 36003035 14 Tube Delivery 1gp...

Page 23: ...nents 11 Place a small amount of silicone based O ring lubricant on the filter sump O ring Install the O ring into the filter sump groove DISINFECTION PROCEDURE CAUTION WEAR SAFETY GLASSES AND SANITAR...

Page 24: ...V head Do not get the UV control module or connectors wet 3 Remove sump from UV head and set aside CAUTION Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiven...

Page 25: ...packet on the outside of the open end of the quartz sleeve only on the area that will engage with the O ring CAUTION Apply even pressure to push the quartz sleeve into the UV head To avoid breakage m...

Page 26: ...VE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a p...

Reviews: