9
ACTIVATE SYSTEM
CAUTION:
Verify that inlet and outlet ports are connected to
appropriate inlet/outlet pipes (see Figure 3).
1. Plug system into an electrical outlet. If the LED Indicator (Item 8)
does not light up within one minute, verify UV lamp is securely
plugged into UV control module. It is normal for the LED indicator
to flicker slightly.
NOTE:
The UV lamp should remain on at all times during use
because; repeated starting of UV lamp shortens lamp
life, and UV lamp requires a warm up period of 1-2
minutes.
2. Turn on water supply and check for leaks.
3. Flush system, connectors, and water lines for several minutes to
remove carbon fines.
NOTE:
When an ultraviolet water treatment system is unused
for several hours, water within system could become
warm. This is a normal condition. To cool the water,
dispense water from system.
NOTE:
System is now ready for use.
Service Requirements
Recommended Service Intervals
To ensure the system operates at its optimum level,
certain routine maintenance must be performed.
Frequency of maintenance performance will depend on
source water quality and level of system usage.
CLEAN:
Each time filters are replaced.
DISINFECT:
At least once a year.
UV Lamp #20:
Change Annually
Quartz Sleeve #20:
Clean when changing filters. Replace only if
damaged or cannot be cleaned by non-abrasive methods.
Filters:
Normal life 4-6 months. Filter life will vary due to water
conditions. A reduced flow rate or deteriorating water quality
indicates that filters must be changed.
Summary of Contents for Aqua Flo ADDON Series
Page 2: ......