TP500/TP500S Programming Procedure
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
NOTE:
Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Menu/Select button, used to enter programming modes
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time - varies depending on function
Main Screen
If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
With system on or OFF move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
ON
1
10
S1
As soon as Switch #1 is placed
in the ON position, the temperature will show
“T” after it instead of F or C, indicating the
System is in Test Mode
Software Setups
Under the TEST Menu, the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
You will have 1 minute
to complete the setup change after you manually exit Priming Mode. (Once familiar with the process,
the Setup change should take less than 15 seconds.)
Press Menu/Select button
“TEST” will appear
Press Menu/Select the system will reset and
go into priming mode
17