Page 3: ...uired Parts Required Error Messages FLO Message FLC Message Prr Message HL Message Programming Low Level Programming Identified Problems Nothing Works Spa Is Not Heating Pump Does Not Work Ozonator Do...

Page 4: ...cable Multi meter and clamp on Ammeter Accurate thermometer GFCI tester optional Parts Required Spaside control Temperature sensor Hi Limit sensor 30A Fuse System Board Pre Test Prior to the service c...

Page 5: ...switch A system with a pressure switch displaying the pressure or flow switch not activated message will not be corrected by replacing the pressure switch Verify that the pump is working If the pump i...

Page 6: ...r flow switch Pressure Switch Adjustment Important Test Fill spa to maximum water level Apply power and operate jets on high speed to establish full water flow throughout the system Turn OFF all power...

Page 7: ...e the probe in the spa water If this solved the problem replace the sensor Replace the printed circuit board if the problem has not been corrected ECO 5 6100 Error Messages High Limit Sensor Over Heat...

Page 8: ...f Open the access panel on the control box With a voltmeter read the voltage between P10 and P17 on the printed circuit board This is the power supply for the heater relay coil If you do not read 120...

Page 9: ...mming Low Level Programming It is possible to change the parameters of the Equipment System by positioning specific jumpers located on the system board Jumper 1 Position 1 High Current 240vac There is...

Page 10: ...the Line 1 fuse is good If you are getting good voltage readings but nothing seems to work verify that the Spaside control is properly connected to the system circuit board and external receptacle if...

Page 11: ...heating replace the printed circuit board If the Heater On indicator does illuminate Open the access panel on the control box and measure the voltage between P10 and P17 at the system circuit board Re...

Page 12: ...he keypad is not defective If the keypad is defective replace the spaside control If the keypad is not defective replace the printed circuit board Pump Indicator does illuminate If the Pump indicator...

Page 13: ...es not work perform the following tests to correct the problem It is important to measure voltage when the light is connected to the System Power must remain on The first step is to replace the bulb o...

Page 14: ...the following tests to correct the problem Make sure the Programming Jumpers are set properly Refer to Programming Replace spaside control with a spare Check to see if the keys are responding If they...