14
15
Continued
Fault
Cause
Solution
Remarks
Pumped water does
not flow constantly
a) Suction pipe is too small.
a) Enlarge inlet pipeline
b) There is not sufficient water
in pump water inlet.
b) Improve system and
increase coming water
c) Liquid level is Iow.
c) Try to lift liquid level.
d) Pump inlet pressure is too
low compared with water
temperature, pipeline loss
and flow.
d) Improve system and
try to increase the inlet
pressure.
e) Suction pipe is partly
blocked by impurities.
e) Check and clear
impurities.
Pump runs but gives
no water
a) Suction pipe is blocked by
impurities.
a) Check and clean
suction pipe.
b) Foot valve or check valve is
closed.
b) Check and repair foot
valve or check valve.
c) Leakage in suction pipe.
c) Check and repair
suction pipe.
d) There is air in suction pipe
or pump.
d) Refill liquid,
release air.
Pump runs
backwards when
switched off
a) Leakage in suction pipe.
a) Check suction pipe
b) Foot valve or check valve is
defective.
b) Check and repair foot
valve or check valve.
c) Foot valve is blocked in
opened or partly opened
position.
c) Check and repair foot
valve.
d) There is air in suction pipe.
d) Check and repair
suction pipe and
release air.
Fault
Cause
Solution
Remarks
Abnormal vibration
or noise from pump
a) Leakage in suction pipe.
a) Check and repair
suction pipe
In the case of
e)
,
users shall not
disassemble
the pump by
themselves.
b) Suction pipe is too small or
suction pipe is partly blocked
by impurities.
b) Enlarge or check
suction pipe.
c) There is air in suction pipe
or pump.
c) Refill liquid to the
pump and vent air.
d) The comparison of the
delivery head of device with
delivery head of pump is very
low.
d) Improve system or
choose another pump
model.
e) Pump mechanically
blocked.
e) Check and repair
pump.
Continued
VIII. IMpORTANT NOTICE
1. Customers will not be advised if this manual is updated.
2. Pump will be guaranteed for one year under normal operation with the correct
model. Wearing part is not included.
3. Users shall be responsible for the damage if they disassemble the pumps by
themselves in guaranteed period.