HYDROO HDROO Series Operation Manual Download Page 2

2

3

DECLARATION OF CONFORMITY 

Machinery Directive: 98/37/EC, 2006/42/EC 

Low Voltage Directive: 2006/95/EC 

Electromagnetic Compatibility Directlve: 2004/108/EC 

Name of manufacturer or supplier

HYDROO PUMP INDUSTRIES, S.L. 

Full postal address including country of origin 

C/ La Banyeta Nova, 11 - P.I. La Banyeta, 17843 Palol de Revardit (Girona) - Catalonia - Spain

Description of product 

HF/HX/HN  is a kind of horizontal multistage non-self priming multistage centrifugal pump.

Name, type or model, batch or serial number 

Name: Light Horizontal Multistage Centrifugal Pump 
Model: HDROO SERIES (HF, HX, HN)

Standards used, including number, title, issue date and other relative documents

Machinery directive 98/37/EC   

 

Ecodesign Directive 2009/125/EC

Machinery directive 2006/42/EC 

 

- Commission Regulation 547/2012

- Standard: EN809:1998 + A1:2009 

 

- Commission Regulation 640/2009 

Place of Issue

 

Palol de Revardit, Spain

Name of authorlsed representative

Miquel Coma

Position of authorlsed representative

CEO

Declaration 

I declare that as the authorised representative, the above information in relation to the supply / 
manufacture of this product, is in conformity with the provisions of the above Dlrectlves. For the 
most specific risks of this machine, safety and compliance with the essential requirements of the 
Directive has been based on elements of the above standards.

Authorized representative

Miquel Coma
CEO

I. AppLICATIONS AND CONDITIONS 

 4

II. DEFINITION OF MODEL 

5

III. CONSTRuCTION 

 6

IV. INSTALLATION AND CONNECTION 

V. START-up, OpERATION AND MAINTENANCE 

11

VI. ASSEMbLE AND DISASSEMbLE 

 12

VII. FAuLT FINDINg AND SOLuTION CHART 

13

VIII. IMpORTANT NOTICE 

 15

CONTENTS

Summary of Contents for HDROO Series

Page 1: ...HYDROO Pump Industries SL HF HX HN Light Horizontal Multistage Centrifugal Pump Operation Manual HDROO SERIES ...

Page 2: ...25 EC Machinery directive 2006 42 EC Commission Regulation 547 2012 Standard EN809 1998 A1 2009 Commission Regulation 640 2009 Place of Issue Palol de Revardit Spain Name of authorlsed representative Miquel Coma Position of authorlsed representative CEO Declaration I declare that as the authorised representative the above information in relation to the supply manufacture of this product is in conf...

Page 3: ...Liquid transferring circulation boosting Hot or cold water Feed proportioning system of food drinking agriculture etc 2 Operation conditions Liquid temperature Normal temperature type 15ºC 70ºC Hot water type 15ºC 110ºC Flow range 0 5 28 m3 h Max pressure 10 bar Liquid pH range pH5 9 Max ambient temperature 40ºC The Max suction pressure is limited by max operating pressure Min inlet pressure Refer...

Page 4: ...4 Impeller 7 Discharge 8 Mechanical Seal 10 Base plate 11 Staybolt 12 Diffuser 12a Neck ring retainer 12b Neck ring 13 Support diffuser W O this part in 2 3 stages pump 14 Impeller sleeve 15 Sleeve 1 W O this part in HF HX HN 2 17 Seal ring 18 Impeller sleeve S W O this part in 2 3 stages pump 19 First impeller cover 20 Nut 23 O ring 24 Spring washer 25 Nut 28 Screw 29 Spring Washer 31 Washer 32 M...

Page 5: ...he motor nameplate Motor shall be connected with a fast and effective motor starter to ensure that the motor will not be damaged by lack of phase unstable voltage or overload The motor shall be earthed reliably Caution Before take apart the terminal box cover or dismantle pump make sure that the power supply is switched off Warning Electrical connection and safety devices The pump units should be ...

Page 6: ... fully Fill water in pump in inverse pouring system Close the pump outlet valve release air vent screw on the pump head and open the inlet valve slowly until stable water flows from the air vent screw Then fasten the screw Fill water in pump when liquid level is lower than pump Before installing pump and pipes must be filled with liquid fully and air vented 2 Check the rotary direction Switch on t...

Page 7: ... is not choked Reverse the process above can disassemble a pump VII Fault finding and solution chart Caution Before removing the terminal box cover and before any removal dismantling of the pump make sure that the power supply has been switched off Fault Cause Solution Remarks Motor does not run when started a Power supply failure a Check power supply b Fuses are blown b Replace fuses c Motor is o...

Page 8: ...ck valve is defective b Check and repair foot valve or check valve c Foot valve is blocked in opened or partly opened position c Check and repair foot valve d There is air in suction pipe d Check and repair suction pipe and release air Fault Cause Solution Remarks Abnormal vibration or noise from pump a Leakage in suction pipe a Check and repair suction pipe In the case of e users shall not disass...

Page 9: ...rtners 201902 IOM HFHXHN EN subject to amendments HYDROO Pump Industries SL C La Banyeta Nova 11 P I La Banyeta 17843 Palol de Revardit Girona Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...