6

7

III. CONSTRuCTION

· Pump is horizontal, multistage, section type. Pump shaft is the extended
  motor shaft. Axial suction and radical discharge;
· HDROO Series are mainly composed of motor, suction head, discharge head, 

diffuser, impeller, pump shaft, mechanical seal, etc.

· The key parts of pump---diffuser, impeller, inlet and outlet chamber,
  pump shaft are made of stainless steel. The suction head and discharge head
  of HF is made of cast iron.
· Mechanical seal is single face seal. Seal part is made of Silicon Carbide/
  Carbide. Other material for Seal part is also available on demand of
 customers.
· The standard connection type is pipe thread connection, which is conformable
  with GB7307 standard. See the following pump structure figure.

HF, HX, HN 2  4-080701

Fig. 1B HF, HX, HN 2, 4 Pump structure

1. Suction

2. Plug

3. Bearing (W/O this part 

  in 2-3 stages pump)

4. Impeller

7. Discharge

8. Mechanical Seal

10. Base plate

11. Staybolt

12. Diffuser

12a. Neck ring retainer

12b. Neck ring

13. Support diffuser (W/O this  

 

part in 2-3 stages pump)

14. Impeller sleeve

15. Sleeve 1 (W/O this part 

 

in HF,HX, HN 2) 

17. Seal ring

18. Impeller sleeve(S) (W/O 

this part in 2-3 stages pump)

19. First impeller cover

20. Nut

23. O ring

24. Spring washer

25. Nut

28. Screw

29. Spring Washer

31. Washer

32. Motor

HF, HX, HFN 8, 12, 16, 20-080701

Fig. 1D HF, HX, HN 8, 12, 16, 20 Pump structure

1.- Suction

2.- Plug

3.- Bearing (W/O this part 

in 1-2 stages pump)

4.- Impeller

7.- Discharge

8.- Mechanical Seal

10.-  Base plate

11.- Staybolt

12.- Diffuser

(W/O this part in HF, HX, HN 

20 1-3 stages pump)

12a.- Neck ring retainer

12b.- Neck ring

12c.- Last diffuser

(Only for HF, HX, HN 20)

13.- Support diffuser

(W/O this part in 1-2 stages 

pump)

14.- Impeller sleeve

15.- Impeller sleeve(L)

(W/O this part in 1-2 stages 

pump)

17.- Seal ring

18.- Impeller sleeve(S)

(W/O this part in 1-2 stages 

pump)

19.- First impeller cover

20.- Nut

23.- O ring

24.- Washer

2S.-  Nut

28.- Screw

29.- Spring washer

31.- Washer

32.- Motor

Summary of Contents for HDROO Series

Page 1: ...HYDROO Pump Industries SL HF HX HN Light Horizontal Multistage Centrifugal Pump Operation Manual HDROO SERIES ...

Page 2: ...25 EC Machinery directive 2006 42 EC Commission Regulation 547 2012 Standard EN809 1998 A1 2009 Commission Regulation 640 2009 Place of Issue Palol de Revardit Spain Name of authorlsed representative Miquel Coma Position of authorlsed representative CEO Declaration I declare that as the authorised representative the above information in relation to the supply manufacture of this product is in conf...

Page 3: ...Liquid transferring circulation boosting Hot or cold water Feed proportioning system of food drinking agriculture etc 2 Operation conditions Liquid temperature Normal temperature type 15ºC 70ºC Hot water type 15ºC 110ºC Flow range 0 5 28 m3 h Max pressure 10 bar Liquid pH range pH5 9 Max ambient temperature 40ºC The Max suction pressure is limited by max operating pressure Min inlet pressure Refer...

Page 4: ...4 Impeller 7 Discharge 8 Mechanical Seal 10 Base plate 11 Staybolt 12 Diffuser 12a Neck ring retainer 12b Neck ring 13 Support diffuser W O this part in 2 3 stages pump 14 Impeller sleeve 15 Sleeve 1 W O this part in HF HX HN 2 17 Seal ring 18 Impeller sleeve S W O this part in 2 3 stages pump 19 First impeller cover 20 Nut 23 O ring 24 Spring washer 25 Nut 28 Screw 29 Spring Washer 31 Washer 32 M...

Page 5: ...he motor nameplate Motor shall be connected with a fast and effective motor starter to ensure that the motor will not be damaged by lack of phase unstable voltage or overload The motor shall be earthed reliably Caution Before take apart the terminal box cover or dismantle pump make sure that the power supply is switched off Warning Electrical connection and safety devices The pump units should be ...

Page 6: ... fully Fill water in pump in inverse pouring system Close the pump outlet valve release air vent screw on the pump head and open the inlet valve slowly until stable water flows from the air vent screw Then fasten the screw Fill water in pump when liquid level is lower than pump Before installing pump and pipes must be filled with liquid fully and air vented 2 Check the rotary direction Switch on t...

Page 7: ... is not choked Reverse the process above can disassemble a pump VII Fault finding and solution chart Caution Before removing the terminal box cover and before any removal dismantling of the pump make sure that the power supply has been switched off Fault Cause Solution Remarks Motor does not run when started a Power supply failure a Check power supply b Fuses are blown b Replace fuses c Motor is o...

Page 8: ...ck valve is defective b Check and repair foot valve or check valve c Foot valve is blocked in opened or partly opened position c Check and repair foot valve d There is air in suction pipe d Check and repair suction pipe and release air Fault Cause Solution Remarks Abnormal vibration or noise from pump a Leakage in suction pipe a Check and repair suction pipe In the case of e users shall not disass...

Page 9: ...rtners 201902 IOM HFHXHN EN subject to amendments HYDROO Pump Industries SL C La Banyeta Nova 11 P I La Banyeta 17843 Palol de Revardit Girona Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...