HYDROO HDROO Series Operation Manual Download Page 6

10

11

3. HF, HX, HN  dimensions (mm)

Model

D1 D2

N

E

L

L1

L2

L3

d

D

H

K

M

weight

Three

phase

Single

phase

Single

phase

Kg

HF, HX, HN 2-20

G1 G1 110 182

305

84

87

138 9

145 215

230

96

108

15

HF, HX, HN 2-30

323

102

105

HF, HX, HN 2-40

341

120

123

HF, HX, HN 2-50

359

138

141

HF, HX, HN 2-60

422

156

159

170 225

245

100

17

HF, HX, HN 4-20

G1¼ G1 110 182

329

102

105

138 9

145 215

230

96

108

15

HF, HX, HN 4-30

356

129

132

HF, HX, HN 4-40

416

156

162

170 225

245

100

17

HF, HX, HN 4-50

455

183

188

HF, HX, HN 4-60

482

210

213

HF, HX, HN 8-10

G1½G1¼ 118 228

395

108

126

138 9

170 230

265

100 108

20

HF, HX, HN 8-20

395

108

126

HF, HX, HN 8-30

425

138

156

25

HF, HX, HN 8-40

490

168

186

180 240

270

28

HF, HX, HN 8-50

520

198

216

30

HF, HX, HN 12-10

G1½G1½

118 268

395

108

126

138 9

170 230

265

100

108

20

HF, HX, HN 12-20

395

108

126

21

HF, HX, HN 12-30

460

138

156

180 240

270

25

HF, HX, HN 12-40

490

168

186

29

HF, HX, HN 12-50

126 240 555

198

216

195 270

/

/

34

HF, HX, HN 16-10

G2 G2

117 227 423

126

151

138 9

180

230

265

100

108

18

HF, HX, HN 16-20

118 228 455

126

151

240

270

27

HF, HX, HN 16-30

130 240 561

171

196

195 270

/

/

33

HF, HX, HN 16-40

120 230 621

216

340 140 12 220 270

/

/

190

41

HF, HX, HN 20-10

G2 G2

117 227 423

126

151

138 9

180

230

265

100 108

18

HF, HX, HN 20-20

118 228 455

126

151

240

270

27

HF, HX, HN 20-30

120 230

576

171

294

140 12 220 270

/

/

190

41

HF, HX, HN 20-40

621

216

340

44

V. START-up, OpERATION AND MAINTENANCE 

Caution: It is prohibited to run without liquid, which will damage mechanical 
seal and sliding bearing.

1. Do not start the pump until it has been filled with water or liquid fully.

· Fill water in pump in inverse pouring system.
  Close the pump outlet valve, release air vent screw on the pump head, and open the 

inlet valve slowly until stable water flows from the air vent screw.

  Then fasten the screw.
· Fill water in pump when liquid level is lower than pump. Before installing,
  pump and pipes must be filled with liquid fully and air vented.

2. Check the rotary direction

Switch on the power supply and view the rotary direction by viewing the
motor fan. From the motor end, pump shall run counter-clockwise.

3.Check before pump start-up

· Check whether the pump is fixed securely.
· Check whether pump is filled with water fully and check whether liquid
  can flow freely.
· Check whether the voltage of power supply is stable.
· Check whether it turns correctly.
· To make sure all pipe lines are connected tightly and can supply water
 normally.
· The valves in the inlet pipe line are completely opened.
· The outlet valve shall be opened slowly after the pump is started up.
· Check the operation pressure if pressure meter is installed.
· Check all the controls for normal operation. If the pump is controlled
  by pressure switch, check and adjust the starting pressure and stopping pressure.

Check the full load current to make sure it not surpasses the max allowed

 current.

4. Frequency of pump starts

· Pump should not be started too frequently. It is suggested pump shall
  not be started more than 100 times per hour if the motor power is less or equal
  to 4kW. When motor power is big than 4kW, pump shall not be started
  more than 20 times in one hour.
· Suggestion: When pump running, flow should be controlled at the range
  of 0.5-1.3 times of rated flow.
· There should be no noise when pump running. If there is something
  wrong, stop pump and check it and repair.

Summary of Contents for HDROO Series

Page 1: ...HYDROO Pump Industries SL HF HX HN Light Horizontal Multistage Centrifugal Pump Operation Manual HDROO SERIES ...

Page 2: ...25 EC Machinery directive 2006 42 EC Commission Regulation 547 2012 Standard EN809 1998 A1 2009 Commission Regulation 640 2009 Place of Issue Palol de Revardit Spain Name of authorlsed representative Miquel Coma Position of authorlsed representative CEO Declaration I declare that as the authorised representative the above information in relation to the supply manufacture of this product is in conf...

Page 3: ...Liquid transferring circulation boosting Hot or cold water Feed proportioning system of food drinking agriculture etc 2 Operation conditions Liquid temperature Normal temperature type 15ºC 70ºC Hot water type 15ºC 110ºC Flow range 0 5 28 m3 h Max pressure 10 bar Liquid pH range pH5 9 Max ambient temperature 40ºC The Max suction pressure is limited by max operating pressure Min inlet pressure Refer...

Page 4: ...4 Impeller 7 Discharge 8 Mechanical Seal 10 Base plate 11 Staybolt 12 Diffuser 12a Neck ring retainer 12b Neck ring 13 Support diffuser W O this part in 2 3 stages pump 14 Impeller sleeve 15 Sleeve 1 W O this part in HF HX HN 2 17 Seal ring 18 Impeller sleeve S W O this part in 2 3 stages pump 19 First impeller cover 20 Nut 23 O ring 24 Spring washer 25 Nut 28 Screw 29 Spring Washer 31 Washer 32 M...

Page 5: ...he motor nameplate Motor shall be connected with a fast and effective motor starter to ensure that the motor will not be damaged by lack of phase unstable voltage or overload The motor shall be earthed reliably Caution Before take apart the terminal box cover or dismantle pump make sure that the power supply is switched off Warning Electrical connection and safety devices The pump units should be ...

Page 6: ... fully Fill water in pump in inverse pouring system Close the pump outlet valve release air vent screw on the pump head and open the inlet valve slowly until stable water flows from the air vent screw Then fasten the screw Fill water in pump when liquid level is lower than pump Before installing pump and pipes must be filled with liquid fully and air vented 2 Check the rotary direction Switch on t...

Page 7: ... is not choked Reverse the process above can disassemble a pump VII Fault finding and solution chart Caution Before removing the terminal box cover and before any removal dismantling of the pump make sure that the power supply has been switched off Fault Cause Solution Remarks Motor does not run when started a Power supply failure a Check power supply b Fuses are blown b Replace fuses c Motor is o...

Page 8: ...ck valve is defective b Check and repair foot valve or check valve c Foot valve is blocked in opened or partly opened position c Check and repair foot valve d There is air in suction pipe d Check and repair suction pipe and release air Fault Cause Solution Remarks Abnormal vibration or noise from pump a Leakage in suction pipe a Check and repair suction pipe In the case of e users shall not disass...

Page 9: ...rtners 201902 IOM HFHXHN EN subject to amendments HYDROO Pump Industries SL C La Banyeta Nova 11 P I La Banyeta 17843 Palol de Revardit Girona Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...

Reviews: