52 Hydro-View User Guide HD0531 Rev 2.0.0
Arm Length
and Type
Automatically
Detected
Figure 35: Hydro-Probe Orbiter Arm Selection
If the arm type is not selectable the connected arm is automatically detected by the Hydro-
Probe Orbiter Head Unit (Figure 35).
During the AutoCal procedure, the ceramic face must be clean, dry and free from
obstruction. Once the ‘AutoCal’ button is pressed, the AutoCal measurement will start and
should take approximately 30 seconds (Figure 36). The sensor will then be ready for use
in the mixer.
Figure 36: AutoCal in Progress
Water
Starts a Water calibration measurement. Ensure that the sensors measurement face is
immersed in water (ideally with 0.5% salt by weight) and is free from other obstructions.
Touch the Water button. The sensor then takes a number of readings to establish an
accurate reference point in water.
Air
Starts an Air calibration measurement. Ensure that the sensors measurement face is in air,
is clean, dry and free from other obstructions. Touch the Air button. The sensor then takes
a number of readings to establish an accurate reference point in air.
6.6.2
Temperature Compensation Screen
These settings should not be changed unless advised to do so by a Hydronix
trained engineer.
Figure 37: Temperature Compensation Screen
Summary of Contents for HV04
Page 4: ...4 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 6: ...6 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 12: ...12 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 14: ...14 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 22: ...Mechanical Installation Chapter 2 22 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 28: ...Electrical Installation Chapter 3 28 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 78: ...Material Calibration Chapter 6 78 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 80: ...Default PIN Codes Appendix A 80 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 82: ...USB Memory Stick file format Appendix B 82 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 84: ...Quick Start Rules Appendix C 84 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 86: ...Frequently Asked Questions Appendix D 86 Hydro View User Guide HD0531 Rev 2 0 0 ...
Page 92: ...Document Cross Reference Appendix G 92 Hydro View User Guide HD0531 Rev 2 0 0 ...