Hydromatic HPUSP125 Owner'S Manual Download Page 2

Safety

2

READ AND FOLLOW 
SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential for
personal injury:

warns about hazards that 

will

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.
The label 

NOTICE

indicates special instructions which are

important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.
1. Read this manual carefully. Failure to follow these

instructions could cause serious bodily injury and/or
property damage.

2. Check your local codes before installing. You must

comply with their rules. 

NOTICE: 

This pump does not require a connection to a

main stack vent, per the National Standard Plumbing Code
(NSPC) 2003 Section 11.7.9.

Hazardous voltage. Can shock, burn or

cause death.

Unplug pump before working on it.

DESCRIPTION

This pump is designed to be used with a sink where a grav-
ity drain line is not available. Attach the pump to the drain
tail piece; the pump will start when water begins to drain.
Uses include basement laundry sinks, wet bars and utility
sinks.

SPECIFICATIONS

Power supply required ....................................115V, 60 HZ.
Liquid Temp. Range....................... 32° – 120°F (0° – 50°C)
Individual Branch Circuit Required (min.)..............15 Amps
Pump Inlet...........................................................1-1/2" NPT
Pump Discharge........................................................1" NPT

Fire or explosion hazard.

Do not use in

explosive atmospheres. Pump water only with this pump.

INSTALLATION 
(SEE FIGURES 1 AND 2)

Electric Shock Hazard.

Plug pump into a

properly grounded, GFCI protected outlet. Do NOT plug in
the pump until after it is completely installed.

Parts supplied with the pump:

• Pump Assembly
• Fiber gasket and O-Ring
• 1” NPT to Slip (Glued) Outlet Adapter
• One-way valve (check valve)
• Discharge shut-off/flow balancing valve.
• Strainer Cup
• 90° Elbow (slip both ends)

Parts purchased separately:

• 1” PVC drain piping including plastic pipe cement and

any required fittings and adapters.

Sink Tail Piece

Fiber Gasket

Close Nipple

Pump Inlet
Port

Lock Ring for
Tail piece

Union Lock 
Ring

Union Mating 
Ring (thread onto
Sink Tail Piece)
Union Mating 
Ring (thread onto
Close Nipple)

Sink Bottom
and Drain Port

Sink Bottom with Drain Port;
Tail Piece integral with Sink

Purchase Separ

ately

P

a

rt

 of Sink

5324 0406

Fiber 
Gasket

O-Ring

Figure 1: Typical method of mounting the pump on the
sink.

Summary of Contents for HPUSP125

Page 1: ...romatic com Installation Operation Parts For further operating installation or maintenance assistance Call 1 419 207 3372 English Pages 2 5 Installation Fonctionnement Pi ces Pour plus de renseignemen...

Page 2: ...ION This pump is designed to be used with a sink where a grav ity drain line is not available Attach the pump to the drain tail piece the pump will start when water begins to drain Uses include baseme...

Page 3: ...g can crack the plastic 8 Install the discharge piping as shown in Figure 2 NOTICE Install the check valve in a vertical position if possible Be sure the flow arrow points AWAY from the pump and be su...

Page 4: ...ing down the drain and jamming the impeller To clear a jammed impeller 1 Unplug the Pump 2 Close the discharge shutoff valve 3 Bail out the sink as much as possible 4 Disconnect the two unions lower t...

Page 5: ...product that has been subject to negligence misapplication improper instal lation or maintenance In the event a three phase submersible motor is operated with single phase power through a phase conver...

Page 6: ...ectera de l eau elle d marrera Elle peut tre branch e sur un vier de buanderie de sous sol le minibar ou un vier auxiliaire SP CIFICATIONS Courant requis 115 volts 60 Hz Temp ratures du liquide De 32...

Page 7: ...ller le clapet antiretour en position verticale S assurer d orienter sa fl che l OPPOS de la pompe et d installer correcte ment Dessus l horizontale ou Ce c t en haut la verticale Risque d incendie ou...

Page 8: ...pompe 2 Fermer le robinet du refoulement 3 Vider le plus possible l vier 4 D brancher les deux raccords unions poser la pompe sur le plancher et la mettre de c t Voir la Figure 3 5 D poser les quatre...

Page 9: ...installation ou 18 mois partir de la date de fabrication Notre garantie ne s appliquera pas tout produit qui a t soumis une n gligence une mauvaise utilisa tion une mauvaise installation ou un mauvai...

Page 10: ...os de uso general ESPECIFICACIONES Suministro de potencia requerido 115V 60 HZ Gama de temperatura del l quido 32 120 F 0 50 C Requiere un ramal individual min 15 Amperios Admisi n de la bomba 1 1 2 N...

Page 11: ...en posici n vertical si es posible Verifique que la flecha de flujo apunte en la direcci n ALEJADA de la bomba y verifique que se instale con este lado hacia arriba horizontal o este extremo hacia ar...

Page 12: ...uar el fregadero lo m s posible 4 Desconecte las dos uniones baje la bomba al suelo y desl cela fuera del fregadero consulte la Figura 3 5 Saque los cuatro tornillos de la caja consulte la Figura 4 6...

Page 13: ...instalaci n o por 18 meses desde la fecha de fabricaci n Nuestra garant a no corresponde a ning n producto que haya estado sujeto a negligencia mala aplicaci n instalaci n o mantenimiento inadecuados...

Reviews: