background image

 6

www.hydrofarm.com

if set, will operate according to the default 

current time, but not the real current time. You 

are highly recommended to set the current 

time.

4. 

To set for timed operation, press 

TIMER/

MODE

 a third time and “Timing on” will 

display. Use the “

+

” button to change hour 

and the “

” button to change minutes. The 

timer is in 24-hour format.

Run

Set

5. 

After you press 

TIMER/MODE

 a fourth 

time, “

Timing off

” will display. Use the “

+

” 

button to change hour and the “

” button 

to change minutes.

Run

Set

TIP:

 You can choose to skip the Timing on and 

Timing off setting by pressing the 

TIMER/

MODE 

button to exit. If so, you must manually 

power the machine on or off each time by 

pressing the 

POWER

 button.

6. 

Press 

TIMER/MODE

 a fifth time to exit the 

setting mode.

Run

OPERATIONS

Non-timed dehumidifying operation to 

the desired humidity level

When the timer is not set, the unit 

dehumidifies toward the humidity set point 

and automatically goes to the standby mode 

when the set point is achieved. After the 

ambient humidity increases more than 3%, the 

dehumidifying function operates again. The 

machine will continue working in this pattern 

until it is manually powered off.

INSTRUCTION MANUAL

Due to the 3-minute on/off delay design to 

protect the working components (

see On/

Off Delay, page 7

), the humidity reading 

may go up more than 3% while the machine 

remains in the standby mode since it is within 

the 3-minute delay protection period. This 

usually happens in the condition that the 

ambient humidity is high. It is not a machine 

malfunction.

Timed dehumidifying operation to the 

desired humidity level

 When the timer is set, the machine will 

operate according to the humidity set point 

(

see page 5, step 2

), only after the Timing On 

time and before the Timing Off time. Before 

the Timing On time and after the Timing 

Off time, the machine is in standby mode. 

Unless the power supply cord is unplugged, 

the machine remembers all set points in the 

standby mode and will automatically operate 

according to the timer setup every day.
 You can manually override the timer function 

to start or stop the dehumidifying function 

by pressing the 

POWER

 button. The machine 

resumes to the timer mode in the next 24-hour 

cycle.

Automatic Defrost

 The unit will automatically go into defrost 

mode when frost forms on the evaporator coil. 

The screen shows “

Defrost

.” After 15 minutes 

of defrost time the unit will resume operation. 

When in the defrost mode, the unit does not 

dehumidify.

Continuously dehumidify operation

When the machine is in continuous operation, 

the desired humidity set point is still 

remembered but is deactivated. The machine 

will continuously dehumidify, no matter what 

the humidity set point is, until it is manually 

powered off or timed off.

1. 

 Press  the 

CONTINUOUS OPERATION

 

button to enter the continuous operation 

mode. The screen will show “

Continuous

.”

Summary of Contents for AADHC100P

Page 1: ...INSTRUCTION MANUAL DEHUMIDIFIERS AADHC100P AADHC60P ...

Page 2: ...ax condenser pressure 3 6 MPa 3 6 MPa Max evaporator pressure 1 2 MPa 1 2 MPa Freon type capacity R410a 390g R410a 400g Grade of waterproof IP X1 IP X1 Weight 73lbs 77lbs Operating ambient temperature 41 F 95 F 41 F 95 F Test conditions 86 F RH80 86 F RH80 WARNINGS Please follow the below safety guidelines when using the dehumidifier Unplug the power supply when cleaning or storing the unit Do not...

Page 3: ...pening for draining pipe Water tank handle Power cord PRODUCT DRAWINGS INSTRUCTION MANUAL FRONT FRONT OPEN BACK Outer cover Front cover Wheel Handle Control panel Power cord Front panel hinges Hot air vents Power cord ...

Page 4: ...e The end of the drainage pipe should not be higher than the water tank outlet If the drainage pipe end is higher than the outlet water will not drain properly and could damage components DRAINAGE INSTALLATION DRAINAGE WITH THE BUILT IN WATER TANK The unit is designed to use the built in water tank for drainage by default When the tank is full the screen will display FULL and also make a buzzing s...

Page 5: ... Press the POWER button to start the machine The screen will display Run and Current the present humidity Run 2 To set the desired humidity press the TIMER MODE button The screen shows Set and the machine enters into the set mode When in the set mode you can increase or decrease the humidity from the default setting to your desired level by using the or buttons Run Set ATTENTION The machine defaul...

Page 6: ...3 while the machine remains in the standby mode since it is within the 3 minute delay protection period This usually happens in the condition that the ambient humidity is high It is not a machine malfunction Timed dehumidifying operation to the desired humidity level When the timer is set the machine will operate according to the humidity set point see page 5 step 2 only after the Timing On time a...

Page 7: ...d Continuous Operation set points will not be remembered when power failure occurs They must be reset when the power is restored The Automatic Restart feature allows the unit to be used with controllers and timers On Off Delay If the system is turned off after running and you wish to turn it on again there is a 3 minute delay before restart as protection to the working components of the unit MAINT...

Page 8: ...ion Contactyourretailertoreplace thesensor Machinerunsbutdoes notdehumidify Thehumiditysetpointishigher thantheambienthumidity Resetthehumiditytoalowersetpoint orpoweroffthe machineifthedesiredhumiditylevelhasbeenreached Reduceddehumidifier capacity Filtermeshisjammed Cleanthefiltermeshaccordingtomanual Air inand orAir outlouversare jammed CleartheblockagefromAir inand orAir outlouvers Noairinlet ...

Reviews: