42
(3) Press
again to enter into interface
(4) Press
or
to adjust the value setting.
(5) Finally press
once again to save the data or press
to save and quick-exit the parameter setting .
Parameter
Meaning
Range
Default
Remarks
0
To set the entering water
temp. under cooling mode
7-35°C
28°C
Not adjustable
1
To set the entering water
temp. under heating mode
15-42°C
28°C
Adjustable
2
Entry into defrosting time
period
30-90MIN
40MIN
Adjustable
3
Terms of Entry defrosting
function
-30°C to0°C
-7°C
Adjustable
4
Terms of Exit defrosting
2 to 30°C
20°C
Adjustable
5
Time of Exit defrosting
1 to 12MIN
12MIN
Adjustable
6
Mode: 0 Heat 1 Heat and Cool
0-1
0
Not adjustable
7
Mode selection of Electronic
expansion valve
0-1
1(auto)
Adjustable
A
Manual adjustment steps of
electronic expansion valve
18-94
70
Adjustable
L
Entering water temperature
calibration
-9.9-9.9
0
Adjustable
Recover to Factory default setting
Long press
and
simultaneously in 10 second to recover to factory default setting ,it will display “0000”
and then back to “OFF”.
Summary of Contents for 7029988
Page 8: ...6 2 Wymiary mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 9: ...7 Model Hydro S 12 ...
Page 24: ...22 8 Schemat budowy pompy 8 1 Widok urządzenia rozebranego Model Hydro S 5 ...
Page 32: ...30 2 Dimension mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 35: ...33 3 5 Typical arrangement Note This arrangement is only an illustrative example ...
Page 47: ...45 8 Exploded Diagram 8 1 Exploded Diagram Model Hydro S 5 ...
Page 55: ...53 2 Ausmaße mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 69: ...67 8 Explosionszeichnung und Wartung 8 1 Explosionszeichnung Hydro S 5 ...
Page 75: ......
Page 76: ...A0111HYSR302 ...