35
After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
2. Connect power to the heat pump and press the On/Off button
on the electronic control panel. The unit will
start up after the time delay expires .
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump , the unit should also turn off automatically , if not, then adjust the flow switch.
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take
several days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce
the required length of time.
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate .It will turn on wh
en the pool pump runs and shut it off when the pump shuts off. If the pool water level higher than 1 m above or b
elow the heat pump’s automatic adjustment knob, your dealer may need to adjust its initial startup.
Time delay -
The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive
contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this
delay period do not affect the 3-minute duration of the delay.
3.9 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool water,
which may cause condensation on the fins of the evaporator. The amount of condensation may be as much as
several litres per hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.
Summary of Contents for 7029988
Page 8: ...6 2 Wymiary mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 9: ...7 Model Hydro S 12 ...
Page 24: ...22 8 Schemat budowy pompy 8 1 Widok urządzenia rozebranego Model Hydro S 5 ...
Page 32: ...30 2 Dimension mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 35: ...33 3 5 Typical arrangement Note This arrangement is only an illustrative example ...
Page 47: ...45 8 Exploded Diagram 8 1 Exploded Diagram Model Hydro S 5 ...
Page 55: ...53 2 Ausmaße mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Page 69: ...67 8 Explosionszeichnung und Wartung 8 1 Explosionszeichnung Hydro S 5 ...
Page 75: ......
Page 76: ...A0111HYSR302 ...