If a fault was detected it is recorded in the log.
o
At the controller Press the triangle with an exclamation point to see the log file.
VIEW FLOW
Use the B-hvye Pro App
When flow meters are installed and configured, Flow will show on the Home screen.
Setting up flow
The HSC is compatible with the following Flow meters
Data Industrial (Badger Meter) IR-220 Series (PVC models)
Creative Sensor Technologies FSI-T Series
Netafim Reed Switch Register-type Series
Bermad 900 Series Reed Switch Register-type Series
To add a flow meter power down the system following the OSHA standard for The Control of
Hazardous Energy (Lockout/Tagout).
CAUTION: If the HSC is not powered down a potentially hazardous situation exists; minor or
moderate injury could occur Turn off power before installation by following the OSHA standard
for The Control of Hazardous Energy (Lockout/Tagout) (29 CFR 1910.147).
1.
Once the HSC has been powered down attach the flow meter per the flow meter
instructions.
2.
For faster installation use the B-hyve Pro App
3.
Select the sensor input number to be setup (1-2).
4.
Select the Flow Sensor Style and enter the calibration information. Some use K-factor
and Offset, and others are Pulse type. Consult the flow meter supplier’s documentation
for the correct settings or contact Hydro-Rain Technical Support for additional
information.
Brand
K-Factor
Offset
Pulse
Terminal 1
Terminal 2