![Hydro Mobile M2 Series Owner'S Manual Download Page 96](http://html.mh-extra.com/html/hydro-mobile/m2-series/m2-series_owners-manual_2191869096.webp)
95
fi g. 7.19
fi g. 7.20
fi g. 7.21
7 - A
CCESSOIRES
M2 Series motorized units and bridges are shipped with outriggers that may be used at the
top or bottom position.
Plank support outriggers must be installed 5' (1,5 m) from one another. The 72" (183 cm)
outrigger, installed at the bottom position close to the walkway assembly,
must not be
replaced
by any other outrigger. Installing any outrigger other than the 72" (183 cm)
outrigger in front of the walkway will lead to damages to the walkway assembly and could
lead to injuries.
The size and number of outriggers required will vary according to the planking confi guration.
Planking confi gurations of fi ve to eight planks will require the use of additional, optional
components such as longer outriggers and cross boxes. Refer to the
Outrigger Selection
table (fi g. 7.19) for more information about the size and number of outriggers required for
each planking confi guration. Refer also to p. 96 for more information on the installation
and use of doubled outriggers.
For any outrigger confi guration other than those described in this owner’s manual, contact
the Hydro Mobile technical support team.
Outriggers
OUTRIGGER SELECTION TABLE
OUTRIGGER SELECTION TABLE
Planking
confi guration
Outrigger size
0 to 4 planks
2 1/2" x 1 1/2" x 3/16" x 72"
(6,4 cm x 3,8 cm x 0,5 cm x 183 cm)
(standard outrigger, as provided with unit
or bridge)
SINGLE
5 planks *
2 1/2" x 1 1/2" x 1/4" x 84"
(6,4 cm x 3,8 cm x 0,6 cm x 213 cm)
SINGLE
6 planks *
2 1/2" x 1 1/2" x 1/4" x 120"
(6,4 cm x 3,8 cm x 0,6 cm x 305 cm)
DOUBLED
7 planks *
2 1/2" x 1 1/2" x 1/4" x 120"
(6,4 cm x 3,8 cm x 0,6 cm x 305 cm)
DOUBLED
8 planks *
2 1/2" x 1 1/2" x 1/4" x 120"
(6,4 cm x 3,8 cm x 0,6 cm x 305 cm)
DOUBLED
*
Refer to the planking confi guration guidelines for more information.
Planking confi gurations
Planking confi guration guidelines
fig 7 20
PLANKING CONFIGURATIONS – WIDTH ALLOWED ON INSTALLATION
PLANKING CONFIGURATIONS – WIDTH ALLOWED ON INSTALLATION
Number of planks
Motorized unit
Bearing bridge
Cantilever bridge(s)
0 to 4 planks
100% of total width
100% of total width
100% of total width
5 to 8 planks
100% of total width
50% of total width
Max width 5' (1,5 m)
WARNING
The 72" (183 cm) outrigger installed close to the walkway assembly must
not be replaced by any other outrigger
Plank stop pin
Hitch pin clip
Clevis pin and