How to Change the Metering Tip:
•
Remove the chemical feed hose from the barb on the side of the proportioning valve.
•
Unscrew and remove the old tip.
•
Screw in the proper tip for your chemical tip and place the hose back on the barb
Metering Tip Kit (Hydro-Force Item# PDE001)
contains 14 different colored metering tips, allowing
dilution rates from 11:1 up to 427:1. Refer to the chart below to select the tip that meets the dilution rate for
your chemical application.
•
For example: if you require 1-1/2 ounces of chemical per gallon of water, change to the red metering tip
with the dilution rate of 85:1. (11.77 ml of chemical per liter of water)
•
The dilution rates are based on chemicals with water-like viscosity. Thicker (more viscous) chemicals will
dilute at a different rate.
•
For powdered chemicals, a liquid concentrate must be made. Mix the concentrate according to the
manufacturer’s directions, and then select the appropriate metering tip.
•
Contact your distributor or Hydro-Force if you have questions about your chemical.
Metering Tip Application Chart:
Metering Tip Kit – PDE001
Turquoise Tip
Dilution 256 - 1
Red Tip
Dilution 85 - 1
TIP
COLOR
CHEMICAL DILUTION RATES
OZ / GAL (RATIO)
RATES
ml / liter
TAN
0.30 (427:1)
2.34
ORANGE
0.40 (320:1)
3.13
TURQUOISE
0.50 (256:1)
3.91
PINK
0.75 (170:1)
5.88
LIGHT BLUE
1.00 (128:1)
7.81
BROWN
1.12 (114:1)
8.77
RED
1.50 (85:1)
11.77
WHITE
1.75 (73:1)
13.70
GREEN
2.00 (64:1)
15.63
BLUE
2.50 (51:1)
19.60
YELLOW
3.75 (34:1)
29.41
BLACK
5.00 (26:1)
38.46
PURPLE
8.50 (15:1)
66.67
GRAY
11.50 (11:1)
90.90
NO TIP
16.25 (8:1)
125.00
Proportioning Valve
Summary of Contents for Nautilus MX3-200HE
Page 1: ...1 LMANN09 Revised 02 16 2018 Nautilus MX3 200HE Operating Manual ...
Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Page 39: ...39 1 2 6 7 8 9 11 3 8 9 12 4 4 3 10 5 15A 8 9 8 9 39 2 ...
Page 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 52 VACUUM MOUNTS CONNECTIONS 9 54 64 ...
Page 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 103 ...
Page 49: ...49 FLOW 81 92 91 99 96 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 103 39 9 ...
Page 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 98 111 ...