Titan 575 Owner’s Guide: 22
SETTING THE PRESSURE (FOR OPTIONAL HIGH PRESSURE WASHING KIT)
Lower the pressure below 1,200 psi prior to moving the “WATER
PRESSURE
SELECTOR”
valve to “
CARPET CLEANING
” mode. Failure to do so may result
in serious component or engine damage.
Set the cleaning pressure to the desired level as follows.
1. Carpet Cleaning: 300 to 400 psi: Position the “WATER
PRESSURE SELECTOR”
valve to “CARPET CLEANING” mode (if equipped). The system is designed to shut
off above 1,200 psi to protect the heat exchanger system.
2. Hard Surface Cleaning: 1,200 psi or as indicated on tool. Position the “WATER
PRESSURE SELECTOR” to “CARPET CLEANING” mode (if equipped). The system
is designed to shut off above 1,200 psi to protect the heat exchanger system.
3. Pressure Washer Cleaning (if equipped): 2,000 psi or as indicated on tool. Position
the “WATER PRESSURE SELECTOR” to “PRESSURE WASHING” mode (if
equipped).
Do NOT apply a vacuum load while using the Titan 575 in “PRESSURE WASHING”
mode. Doing so may cause the machine to overheat.
4.
Turn the “CHEMICAL SYSTEM” switch to the “PRIME” position to purge any air
from the system (see Figure 4-4).
a.
With the truckmount running at full throttle
,
block off the vacuum intake to the
recovery tank. The vacuum gauge
should read 12” Hg. This will assist in
priming the chemical system.
b.
Allow the chemical to flow through
the chemical meter at full flow for 30
seconds.
c.
Turn the “CHEMICAL SYSTEM”
switch to “ON.” The restriction can
now be removed from the vacuum
inlet.
d. While spraying solution from the
cleaning tool, adjust the chemical
flow by turning the “CHEMICAL
METERING CONTROL” knob.
5. Begin cleaning.
Figure 4. Location of
Chemical System Switches
Summary of Contents for Titan 575