CTS 400 Flex Owner’s Guide: 36
To freeze guard the hoses and wand perform step 6 with the items to be freeze
guarded attached.
Recovering Antifreeze for Re-Use
1. Attach all hoses and wands which have been freeze guarded to the truckmount.
2. Attach the incoming water source to the front of the truckmount.
3. Start the truckmount.
4. Spray the solution through the hoses and wands into a sealable container until all
signs of antifreeze are gone.
Freeze Protection of the Pump-In System
1. Drain the fresh water tank.
2.
Remove the garden hose adapter from the pump-in pump hose and position the
hose so it is pointing outside the van.
3.
Turn on the pump-in pump and run for 1-2 minutes until all the water is purged from
the hose.
The next time the truckmount is used it may take a few minutes before the water
box begins to fill.