CTS 400 Flex Owner’s Guide: 18
START-UP PROCEDURE (ALL MODES)
1.
Perform all daily and periodic maintenance as specified in this Owner’s Guide.
2.
Ensure the Solution Control switch is in the “OFF” position.
3. Connect all cleaning tools to the length of hose required to perform the cleaning
job.
4. Turn the key to the “ON” position. Pull the choke and start the truckmount with the
throttle cable fully depressed (“IDLE” position – see
5.
After the engine starts, push the choke in and allow the truckmount to run in “IDLE”
for 2 to 3 minutes to warm up.
6. Pull the throttle cable to full extension and twist the handle clockwise to lock.
Figure 2. CTS 440 Flex Dash Assembly
APO Switch
Ignition and
Key
Tile/Stone
Temperature Control
Choke
Throttle
Tile/Stone
Solution Outlet
Blower Lube
Port
Vacuum Gauge
Pressure Gauge
Water Box
Drain
Incoming Fresh
Water
Solution
Control Switch
Carpet/Uph.
Cleaning
Solution
Outlet
AUX Switch