Page 4-3: Machine Maintenance
Boxxer 421
AS REQUIRED: DE-SCALING
Scale deposits on the interior of the heating system can cause a noticeable loss in
heating performance. Deposits of this kind result from hard water deposits, exces-
sive chemical use, improper chemicals, etc. The frequency with which de-scaling
procedures are required will vary. If your area has particularly hard water or you see
evidence of deposits in the water system, you may have to de-scale monthly.
To de-scale your system, add an appropriate de-scaler chemical to your mix tank.
Circulate it through the heating system. Let it stand. Flush and repeat as necessary.
Clean all screens and strainers, and check them frequently following de-scaling.
NOTE
: If you are using T.M. DeScaler through the flow meter, make sure to run clean
water through the flow meter after this procedure.
To de-scale using the recirculation kit (part no. 078-058), start with an empty mix
tank. Fill a third of the mix tank with T.M. DeScaler. Follow the recommendations on
the T.M. DeScaler label for proportions. Verify that the upper float is not lying hori-
zontal, but floats below.
Attach the recirculation fitting provided in the
kit to the garden hose quick connect (see illus-
tration) and this combination to the front of the
machine.
Attach one section of female/female solution
hose to the outgoing solution fitting on the front
of the machine and the other end to the garden
hose and recirculation fitting combination that
is attached to the front of the machine (or as
many sections as you want, if you wish to de-
scale your hoses).
Start the machine and allow it to run for three to five minutes. Do not leave the T.M.
DeScaler solution in the system. Flush the system with clean water and turn the
machine OFF.
Figure 4-1 Recirculation Fitting
Summary of Contents for Boxxer 421
Page 28: ...Page 8 23 Electrical System Boxxer 421 Figure 1 4 Hard Water Map...
Page 31: ...Page 2 3 Cleaning and Chemicals Boxxer 421...
Page 60: ......
Page 73: ......
Page 74: ......
Page 76: ...Page 8 2 Electrical System Boxxer 421 Figure 8 1 Wiring Schematic D 5149 Rev H...
Page 77: ...Page 8 3 Electrical System Boxxer 421 Figure 8 2 Wiring Schematic D 5148 Rev H Sheet 2...
Page 78: ...Page 8 4 Electrical System Boxxer 421 Figure 8 3 Wiring Schematic D 5148 Rev H Sheet 3...
Page 79: ...Page 8 5 Electrical System Boxxer 421 Figure 8 4 Wiring Schematic D 5148 Rev H Sheet 4...
Page 84: ...Page 9 5 Water and Chemical Boxxer 421 Figure 9 2 Wiring Schematic D 5150 Rev Sheet 1 3...
Page 85: ...Page 9 6 Water and Chemical Boxxer 421 Figure 9 3 Wiring Schematic D 5150 Rev Sheet 2 3...
Page 86: ...Page 9 7 Water and Chemical Boxxer 421 Figure 9 4 Wiring Schematic D 5150 Rev Sheet 3 3...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ...Page 11 1 Machine Assemblies and Parts List Boxxer 421 Machine Assemblies and Parts Lists...
Page 166: ......