Explanation visual alarm light and audible alarm
If one of the below mentioned alarms are activated, the Hydraloop unit will stop offering recycled water and
will offer backup water unless in case of Water distribution pump failure.
High water alarm:
Audible alarm 2 beeps every minute, visual alarm 2 light pulses every minute
Air pump alarm:
Audible alarm 3 beeps every minute, visual alarm 3 light pulses every minute
UV-C disinfection lamp alarm:
Audible alarm 4 beeps every minute, visual alarm 4 light pulses every minute
Water circulation failure:
Audible alarm 5 beeps every minute, visual alarm 5 light pulses every minute
Water distribution pump failure:
Audible alarm 6 beeps every minute, visual alarm 6 light pulses every minute
In case of a water distribution pump failure, it can happen that water distribution to the users is blocked or
limited
If you need assistance call your Hydraloop dealer or contact Hydraloop technical support via email
or phone on number:
+31 88 100 3500 (EU) | +1 414 89 500 21 (USA)
13.
Maintenance
We recommend a check performed by a Hydraloop accredited installer once every two years.
This check contains the following elements:
-
Descale the Hydraloop unit with a citric acid solution to descale the integrated water tanks.
-
Remove, clean and descale the air diffuser.
-
Replace the rubber membranes of the air pump every three years (according to the manual of the air
pump supplier).
-
Replace the UV light bulb every two years by unscrewing the lid on the UV-C lamp housing.
-
Effluent samples can be collected using the water valve that is connected to the laundry machine.
In regions with very high levels of water hardness more frequent descaling of the water tanks may be necessary.
Please check water hardness during installation.