12
D/E/F 5.601.B.6/1
1.15
E
3. MODEL CODE
4. TECHNICAL SPECIFICATIONS
The cooling capacity is dependent on the flow rate
(see brochure)
5. INSTALLATION
The mounting position of the PTK is optional.
The PTK must be positioned so that the cooling air can
flow in and out freely.
The cooler element inlet and outlet connections can be selected by the
user.
When mounting the fan wheel, the collar must be pushed right to the end
of the motor shaft.
Then the collar must be secured by tightening the threaded pin.
If using motor construction types V1 and V15 the cooler element can
simply be turned (see diagram).
tank
Mounting of cooler element using
motor constructions V1 and V3
fan wheel
threaded pin
motor connection
collar
heat exchanger
pump
flange
pump
connection
damping
ring
clamping
ring
INFORMATION
IMPORTANT
PTK - 250 / M / 140 / FB092 - E / F3
Type
PTK = flexible bell housing
with oil-air cooler
Nominal size for ICE standard motor
Mineral oil resistance
M
= (see 2.1)
Bell housing length N
Bore template code for pump connection
Type of damping ring
Accessories
F3
= bell housing foot bracket