Performing maintenance | 7
MoWa OLFP-1-T002 4469047 en-us lq
43 / 64
2.
Carry out the pressure release of the filter housing.
In order to do so, fully screw out the vent screw counter-
clockwise by means of an Allen wrench
= 6 mm.
While doing this, hold the adapter by means of a wrench
= 19 mm.
3.
Open the drain ball valve to empty the filter housing.
Collect the escaping fluid (=9 liters) in a suitable con-
tainer. Fill the oil back into the tank of the hydraulic sys-
tem or dispose of it in an environmentally-friendly man-
ner.
4.
Loosen the filter lid counterclockwise.
Unscrew the filter lid fully by hand.
CAUTION! Due to spring force, the filter lid springs
up slightly after it has reached the last thread.