HYDAC FILTER SYSTEMS GMBH
Performing maintenance | 7
MoWa OLFP-1-T002 4469047 en-us lq
45 / 64
8.
Press down on the spring with the lid down to the filter
housing and then screw the filter lid by hand clockwise
onto the filter housing.
Tighten the filter lid up to the stop.
9.
Undo the filter cover by a 1/4 turn or by 90° in counter-
clockwise direction.
10.
(I) Open the shut-off device at the inlet IN slowly to avoid
pressure shocks to the filter and fill the filter housing.
(II) During the filling process, take note of the vent bore.
(III) Shut the shut off device at the inlet IN as soon as
fluid escapes.