6 | Manual operation
HYDAC FILTER SYSTEMS GMBH
76 / 120
BeWa MFU-15E_S 4391552d en-us print
6.3.2 Circulation pumping without filtration
In operating mode Recirculation without filtration, replace the
filter element
(900)
with an empty element
(910)
.
A suitable empty element
(910)
can be found in Chapter
Finding spare parts/accessories [
Fig. 27:
Empty element
Fig. 28:
Example of application: Recirculation
ü
Select the right filter element for an operating mode and
exchange this according to Chapter
.
1.
Connect the suction hose to the oil tank/container and fit
the suction hose in it and also secure it against falling
out.
2.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against fall-
ing out.
3.
Connect the filter unit to the voltage source.
4.
Switch the filter unit on at the main switch.
5.
Continuously monitor the filling level in the tank/con-
tainer to be filled during recirculation.