P
art
no
.:
669879
/ S
ta
tus:
19
.07.
2012 E
6
4.3.2 Safe state
The safe state is characterized by the output signal being permanently or cyclically
outside the range 4 ... 20 mA. The higher-level control system must recognise this
situation and put the machine (EUT) into a safe state.
4.3.3 Dangerous failures
A dangerous situation can arise if the linear position transducer of the higher-level
control signals an error position. The circuit and software design, diagnostic measures
and the choice of components all contribute to minimizing the probability of such
failures (see Point 9).
5 Specification
(extract)
The full specification can be found in the user manual for the instrument.
5.1 Diagnostic
times
Diagnostic time
Value
Diagnostic interval
Continuous diagnostics
Process safety time
≤
1000 ms
5.2 Electrical connection
Supply
Value
Supply voltage (V
in
) nominal
9 ... 36 V DC
Residual ripple supply voltage
≤
250 mV
Power consumption
< 2 W
Electrical connection
(cable; 3-core)
white: + U
B
green: 4 ... 20 mA signal output
brown: GND
Reverse polarity protection
Surge protection
Short-circuit protection
Standard
Standard
Standard
5.3 Environment
5.3.1 Temperature range
Environmental conditions
Value
Operating temperature range
- 40 ... 85 °C
Storage temperature range
- 40 ... 100 °C
5.3.2 Mechanical environment
Environmental conditions
Value
Safety class to EN 60529
IP 66 * / 67
Safety class to DIN 40050-9
IP 69 K *
* Modification 100
Summary of Contents for HLT 1000 Analog
Page 2: ...Mat Nr 669876 Stand 19 07 2012 D 2 ...
Page 10: ...Mat Nr 669879 Stand 19 07 2012 D 10 11 CE Konformitätserklärung ...
Page 11: ...Mat Nr 669879 Stand 19 07 2012 D 11 12 TÜV Zertifikat ...
Page 14: ...Part no 669876 Status 19 07 2012 E 2 ...
Page 22: ...Part no 669879 Status 19 07 2012 E 10 11 CE conformity declaration ...
Page 23: ...Part no 669879 Status 19 07 2012 E 11 12 TÜV Certificate ...