P
art
no
.:
669879
/ S
ta
tus:
19
.07.
2012 E
8
9 Safety-related
information
9.1 Performance
level
Instrument HLT
1100-R2-Kxx-Cxx-xxxx-S2PD-000
HLT 1100-00-Kxx-C01-xxxx-S2PD-100
TÜV Nord certificate
44 207 12 388991
Based on
DIN EN ISO 13849-1:2008 – Part 1
PL
d
Architecture Category
2
MTTFd
106.09 years (high)
DC
avg
89.27 % (medium)
CCF
75 points (satisfactory)
Operating life
20 years
9.2 Safety integrity level
Instrument HLT
1100-R2-Kxx-Cxx-xxxx-S2PD-000
HLT 1100-00-Kxx-C01-xxxx-S2PD-100
TÜV Nord certificate
44 207 12 388991
Based on
DIN EN 61508:2001
SIL
2
Classification Type
B
System
Architecture 1oo1D
HFT 0
Demand mode
continuous
PFH
1.15 * 10
-7
/ h
SFF
94.4 %