P
art
no
.:
669879
/ S
ta
tus:
19
.07.
2012 E
7
5.4 Input
data
Input parameters
Value
Measuring length
200 ... 2500 mm
Distance between start of measuring
zone and flange housing
≤
30 mm
Distance between end of rod and end
of measuring zone
≤
63 mm
5.5 Output
data
Output data
Value
Output signal
4 ... 20 mA
Repeatability
+/- 0.1 % FS
Hysteresis
+/- 0.1 % FS
Linearity discrepancy
+/- 0.1 % FS
Accuracy class
+/- 0.5 % FS
Ohmic resistance to GND
200 ... 500
Ω
Reaction time of the output signal
≤
30 ms (10 … 90 %)
6 Operating
elements
The linear position transducer does not have any operating controls. User intervention
is therefore neither possible nor necessary.
7 Commissioning
The user manual instructions must be followed. The geometry and cleanliness of the
installation space, the sound condition of the sealing surfaces and sealing elements,
and the electrical connection are particularly crucial.
8 Interval between repeat testing
The operating life of the position transducer is defined as 20 years. The reliability of
the electrical, electronic and mechanical components is such that no repeat testing is
required during the unit's operating life.
Summary of Contents for HLT 1000 Analog
Page 2: ...Mat Nr 669876 Stand 19 07 2012 D 2 ...
Page 10: ...Mat Nr 669879 Stand 19 07 2012 D 10 11 CE Konformitätserklärung ...
Page 11: ...Mat Nr 669879 Stand 19 07 2012 D 11 12 TÜV Zertifikat ...
Page 14: ...Part no 669876 Status 19 07 2012 E 2 ...
Page 22: ...Part no 669879 Status 19 07 2012 E 10 11 CE conformity declaration ...
Page 23: ...Part no 669879 Status 19 07 2012 E 11 12 TÜV Certificate ...