OF5F / OF5L
Switching on the OF 5
Switching on the OF 5
After switching on the OF5, monitor the suction action via the transparent suction
hose.
If the unit is not feeding medium after several minutes of operation, the pump must
be pre-filled. Switch the motor off and fill the pump via the suction hose.
The special element receptacle renders it unnecessary to vent the filter housing.
Pay particular attention to the clogging indicator during operation. As soon as the
clogging indicator enters the red zone, the filter element must be changed
immediately.
The pressure relief valve in the pump returns the medium to the suction side if the
maximum operating pressure is exceeded.
The motor protection switch contained in the main switch permanently monitors the
nominal current and switches the unit off in case of overload.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 19 / 36
BeWa OF5 F_L 3160337e en-us 2011-01-17.doc