OF5F / OF5L
Changing the Filter Element
Changing the Filter Element
NOTICE
Unsuitable/incorrect filter element
The medium is not filtered
►
Use only filter elements with the type code suffix -KB
(for example:
1300 R 003 BN4HC /
-KB
)
Depending on the version, the unit has an optical back-pressure indicator (2)
(red/green) or a scale in the filter cover. The version with switchover may have an
optional differential pressure gauge (1).
Change the filter element as soon as the back-pressure indicator or differential
pressure gauge is in the red area.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 26 / 36
BeWa OF5 F_L 3160337e en-us 2011-01-17.doc