OF5F / OF5L
Changing the Filter Element
10. Put the cover on.
Observe correct placement of the
O-ring on the filter cover while doing
so. It must not be damaged.
11. Fold the four screws up and turn them
clockwise evenly crosswise.
12. Close the drain valve.
13. Switch the unit on.
14. Check the unit for any leaks.
15. The unit is ready for operation.