FluidAqua Mobil - FAM 10
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 43 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Error message
Cause
Remedy (also see
following detailed
description)
Plug FCU missing
The FCU operating mode
was selected without
connecting the Sub D plug
of the FCU.
Connect the plug to the
FCU or change operating
mode.
Heater fault (only with
option heater)
Oil too hot due to
interruption of oil flow or
faulty thermostat.
Reset the safety
thermostat. Clean the
suction screen. If
necessary shorten the
suction hose.
No parameterblock
Setup settings of the
TD200 deleted.
Re-enter the setup values.
Contact HYDAC.
Electrical fuses
Automatic safety devices have been installed into the control cabinet for the security
of the operating voltage transformer.
Fuse
F1
The primary side of the transformer has 2 A 400 V
F2
The primary side of the transformer has 2 A 400 V
F3
The secondary side of the transformer (socket) has 3 A 250 V
F4
The secondary side of the transformer (control circuit) has 1 A
250 V
F5
The secondary side of the transformer (control circuit) has 1 A
250 V
F6
Contamination Sensor Display CSD (Optional)
F7
Contamination Sensor CS (Optional)