FluidAqua Mobil - FAM 10
Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 47 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Change fluid filter
Step
Description
Malfunction:
"Replace fluid filter"
1.
Press the RESET button.
2.
Switch off the FAM at the main switch.
3.
Close the ball cocks on the IN and OUT connections.
4.
Empty the filter housing via the drain ball valve.
5.
Open the filter housing and remove the filter element. For details see
page 61.
6.
Open the ball cocks on the IN and OUT connections.
7.
Switch on the FAM at the main switch.
8
The fault is repeated after ~ 4 minutes?
->a. Yes
-> proceed to Step 10.
9.
->b. No
-> proceed to Step 11.
10.
Check the differential pressure switch and the feed lines.
11.
The fault is repaired.