FluidAqua Mobil - FAM 10
FAM Set-up and Connection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 32 / 72
BEWA FAM10 3102456f en-us 2012-03-13.doc
2012-03-13
Connecting the inlet (IN)
The suction pressure at the FAM inlet must be -0.4 bar.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Note that the cross-section of the connected hoses/piping, must be at least as large
as the cross-section of the inlet/outlet port sizes.
The shape of the tank connection should be set up in such a way that it will always
be lower than the level of the oil.
NOTICE
Severe contamination
The unit will be damaged
►
Do not prime directly at the bottom of the tank
►
Do not prime in the sump
►
Never prime without a built-in suction screen
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Connect outlet (OUT)
Take care to ensure that the maximum pressure of 2 bar is not exceeded at the
outlet.
NOTICE
OUT connection closed off
The unit will be destroyed
►
Check to be sure that all of the locking fixtures at the outlet are in "open"
position each time before start-up.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.