3.3 External PT100 Sensor
3.3.1 Dimensions and technical specifications
Type designation: TFP 104-000
Type designation: TFP 106-000
Part No.:904696
Order no.: 921330
Technical specifications
Measurement element
PT 100
Measuring range
-40 .. +125 °C ( -40 .. +257 °F)
Probe length
95.5 mm
Probe diameter
6 mm
Electrical installation:
4-pole Binder, series 714 M18 (ZBE 03 connector included)
M12x1, 4 pole (connector not included)
Parts in contact with fluid
Brass
-mark
EN 61000-6-1 / 2 / 3 / 4
Sensor current
0.3 .. 1.0 mA
3.3.2 Electrical Connection
4-pole Binder, series 714 M18
respectively
M12x1, 4 pole
Cable plug connection
M12x1, 4-pole
TFP
Sensor
resistance
1
2
3
4
1
2
3
4
ETS 386X
4-pole
Binder series 714
Screened
connector cable