background image

Main

Power/Safety

Circuit

Item

#

Part

#

Description

1

NA

B

Ͳ

“Ground”

Connection

on

Pump

2

NA

B+

Power

Connection

on

Pump

3

(ELEC

Ͳ

047)

Not

available

as

a

replacement

part.

Replace

with

12V,

Group

27

Deep

Cycle

Marine

Battery.

Replacement

weight

must

be

minimum

50

lb.

4

ELEC

Ͳ

629

Tilt

Sensor

5

ELEC

Ͳ

645

Battery

Charger

6

ELEC

Ͳ

639

Ͳ

1

Charger

Cord

(NEMA

5

Ͳ

15

Ͳ

P/IED

Ͳ

320

C13)

7

ELEC

Ͳ

071

Ͳ

KIT

Emergency

Stop

Button

with

Contact

Block

8

ELEC

Ͳ

073E

Key

Switch

8

ELEC

Ͳ

073EKEY

Spare

Key

9

1002101050

Lower

Control

Assembly

10

1002101350

Upper

Control

Assembly

11

ELEC

Ͳ

551

Joystick

12

ELEC

Ͳ

071

Ͳ

KIT

Emergency

Stop

Button

with

Contact

Block

Not

Pictured

SUB

A13

Main

Cable

Not

Pictured

ELEC

Ͳ

670

Ͳ

2

20

A

AGC

Fuse

Not

Pictured

ELEC

Ͳ

819

Sleep

Timer

Not

Pictured

1002101550

Battery

Cable

Kit

Not

Pictured

1002101099

Drive

Power

Cable

Kit

Part #SUPO-613 
REV E 

Page 34 of 38

Drive

Circuit

Parts

Item

#

Part

#

Description

1

1000108202

Caster

2

1000106451

Drive

Control

Board

(specific

to

this

model/series

only)

3

NA

Brake

Connection

Terminals

4

LAS

Ͳ

M248

Ͳ

1

Ͳ

PC

Limit

Switch

Mounting

Bracket

5

ELEC

Ͳ

123

Ͳ

2

Limit

Switch

6

ELEC

Ͳ

627

Ͳ

4

Brake

Micro

switch

7

ELEC

Ͳ

627

Ͳ

3L

Brake

(Right)

8

ELEC

Ͳ

627

Ͳ

3R

Brake

(Left)

9

ELEC

Ͳ

551

Joystick

10

ELEC

Ͳ

602

&

ELEC

Ͳ

072

Drive

Enable

Button

&

Contact

Blocks

11

ELEC

Ͳ

826

Ͳ

3L

Electric

Drive

Motor

(Left

Side)

12

ELEC

Ͳ

826

Ͳ

3R

Electric

Drive

Motor

(Right

Side)

13

WHEE

Ͳ

707

Wheel,

10”

14

ELEC

Ͳ

610

Ͳ

2

Hour

Meter

15

ELEC

Ͳ

631

Relay

16

WHEE

Ͳ

706

&

HARD

Ͳ

001

Ͳ

2

Wheel,

8”

&

Bearing

(Not

Pictured)

ELEC

Ͳ

809

120

Ohm

Resistor

Part #SUPO-613 
REV E 

Page 35 of 38

Summary of Contents for HB-830

Page 1: ...M TRO MAIN OUBL MA Hy M H Sel Aerial W NTENA AND LESHO ANUA Brid L Models HB 830 f Propel Work Pla ANCE OOTIN AL Lifts s 0 lled atform NG ...

Page 2: ...Service Flash Codes 14 Technical References 15 Hydraulic Schematic 15 Electrical Schematic 16 Wiring Diagrams 18 Wiring Diagram 18 Main Power Safety 20 Drive Circuit 22 Elevate Lower Circuit 24 Troubleshooting 26 Troubleshooting Flowchart 26 Part SUPO 613 REV E Page 2 of 38 Troubleshooting Flowchart Drive Steer Circuit 28 Troubleshooting Flowchart Elevate Lower Circuit 30 Replacement Parts 32 Safe...

Page 3: ...dicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING FAILURE TO FOLLOW THIS WARNING MAY CAUSE DEATH OR PERSONAL INJURY WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION FAILURE TO FOLLOW THIS WARNING MAY CAUSE INJURY OR DAMAGE EQUIPMENT CAUTION indicates a potentially haz...

Page 4: ... The care and maintenance of your battery has much to do with how well this unit functions Battery wiring and water level should be checked monthly Do not overfill When the cells are too full fluid will seep out when charging The solution is at its proper strength when the battery is manufactured Use distilled water and keep fluid up to proper level When required water should be added to battery a...

Page 5: ... REV E Page 8 of 38 Components requiring adjustment Under normal use no components should require adjustment Contact the manufacturer if adjustments are required Examination repair replacement of limited life components With proper use battery maintenance and regular inspection there are no limited life components that require routine replacement Safety devices and systems requiring checks Check s...

Page 6: ...DO SO COULD AFFECT THE SAFETY OF THE OPERATOR MODEL HBǦ830 SERIAL NUMBER ______________ 1 Keep inspection records up to date 2 Record and report all discrepancies to your supervisor 3 A dirty machine cannot be properly inspected Y Yes Acceptable N No Unacceptable R Repaired Description Y N R Visual Inspections Check that there are no damaged dented or bent structural members There are no loose or ...

Page 7: ...cklist WARNING AERIAL PLATFORMS SHALL BE INSPECTED SERVICED AND ADJUSTED TO MANUFACTURER S REQUIREMENTS BY A QUALIFIED MECHANIC PRIOR TO EACH SALE LEASE OR RENTAL AND EVERY 12 MONTHS MODEL NUMBER HBǦ830 SERIAL NUMBER ______________ x Check each item listed below x Use proper operating service and maintenance manual for specific information and settings x If an item is found to be unacceptable make...

Page 8: ...onnections and cabling 7 Remote Fault Check the Communications Bus connectors and wiring Replace the Remote Joystick 8 Power Module Fault Check the Communications Bus connectors and wiring Replace the Power Module 9 Communications Fault One cause of this error is when the unit is powered down without turning off the joystick i e using the emergency stop To clear with the machine on using the key s...

Page 9: ...Part SUPO 613 REV E Page 16 of 38 Part SUPO 613 REV E Page 17 of 38 ...

Page 10: ...Part SUPO 613 REV E Page 18 of 38 Part SUPO 613 REV E Page 19 of 38 ...

Page 11: ...WIRING DIAGRAM MAIN POWER SAFETY CIRCUIT Part SUPO 613 REV E Page 20 of 38 WIRING DIAGRAM MAIN POWER SAFETY CIRCUIT Part SUPO 613 REV E Page 21 of 38 ...

Page 12: ...WIRING DIAGRAM DRIVE CIRCUIT Part SUPO 613 REV E Page 22 of 38 WIRING DIAGRAM DRIVE CIRCUIT Part SUPO 613 REV E Page 23 of 38 ...

Page 13: ...WIRING DIAGRAM ELEVATE LOWER CIRCUIT Part SUPO 613 REV E Page 24 of 38 WIRING DIAGRAM ELEVATE LOWER CIRCUIT Part SUPO 613 REV E Page 25 of 38 ...

Page 14: ...Control Display a Fault Code Check Component or Condition Referenced by Fault Code Part SUPO 613 REV E Page 26 of 38 atteries harger disconnected from machine Are both E Stop buttons off Reset E Stop buttons Pull out at both upper control and lower control locations No Check for loose wiring connections Check for ground connection at pump See wiring diagrams Check for continuity in connections use...

Page 15: ...ntrol board secure Reconnect No Is there moisture or corrosion in any connections No Yes Allow to dry for 24 hours and try again Board probably will need replacement Apply dielectric grease to connectors at main wire harness Yes Replace drive control board and or joystick No Contact CEI for further troubleshooting Consider brake damage broken joystick handle drive enable bad hour meter loose conne...

Page 16: ...nctionning Remove obstruction Replace limit switch or repair connections Part SUPO 613 REV E Page 30 of 38 Is down valve stuck open uid low owered fill to 1 below ervoir Flush valve by simultaneously pressing up switch at base and down switch on platform control for 30 sec Contact CEI for further troubleshooting Check integrity of electrical connections There may be a loose connection or momentary...

Page 17: ...ent revisions Refer to our website www hybridlifts com for more complete part listings and earlier revisions Several parts are model serial number or manufacture date specific Contact your dealer for replacement part availability and pricing Safety and Control Decals Refer to Operator s Manual for decal part numbers and locations Part SUPO 613 REV E Page 32 of 38 Covers Other Item Part Description...

Page 18: ...ctured ELECͲ670Ͳ2 20 A AGC Fuse Not Pictured ELECͲ819 Sleep Timer Not Pictured 1002101550 Battery Cable Kit Not Pictured 1002101099 Drive Power Cable Kit Part SUPO 613 REV E Page 34 of 38 Drive Circuit Parts Item Part Description 1 1000108202 Caster 2 1000106451 Drive Control Board specific to this model series only 3 NA Brake Connection Terminals 4 LASͲM248Ͳ1ͲPC Limit Switch Mounting Bracket 5 EL...

Page 19: ...n Valve 14 HYDRͲ600Ͳ5 High Pressure Hydraulic Hose 15 ELECͲ602 ELECͲ871 Lift Enable Button Contact Blocks 16 ELECͲ133B Up Down Rocker Switch 17 HBͲPHͲ13 Guide Block 18 1000102004 PH Retaining Sleeve 19 HARDͲ702 Spring 20 HBͲPHͲ7ͲP PH Lock 21 ELECͲ123Ͳ2 Limit Switch 22 LASͲM222ͲP LS Plate 23 1000105902 PH PickͲUp Arm 24 LASͲM220ͲP PH Arm 25 ELECͲ629 Tilt Sensor 26 HYDRͲ664 18 V Coil 27 HYDRͲ665 Up ...

Page 20: ...esponsibility for alterations or modifications to the unit or damages caused by any natural disasters such as fire flood wind and lightning THE PREVIOUS WARRANTY STATEMENT IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE If field repair or parts replacement is necessary on any warranted...

Reviews: