Damocles2 2404 dimensions

Damocles2 2404 specifications

Specifications

Specifications

Ethernet

Interface 

RJ45  (100BASE-Tx) – 10 / 100  Mbit 

Supported protocols

ARP, ICMP, UDP / IP: SNMP, 
TCP / IP: HTTP, Modbus / TCP, SMTP, netGSM, HWg-PUSH, XML, IPv6, HTTPs, MQTT

SNMP compatibility

SNMPv3 compatible, partial support for v2.0

DIP Switch

DIP1: RS-232 Setup mode

ON = RS-232 Setup mode on Port 1 (only RS-232 setup works)
OFF = Normal function mode

Restoring factory defaults:

 Toggle the switch 3× during the first 5 seconds after powering up 

DIP2: Security

ON = Security mode – configuration cannot be changed remotely
OFF = Non-secure mode – configuration can be changed remotely

DO – Outputs 

 

Type

OUT1 – OUT4 / Relay contacts (NC-COM-NO)

Max. load

Max.  2 A,  up  to  24 W  (2 A / 12 V  or  0.5 A / 48 V)

Power – on state

Normal (no state memory)

Serial port 1 DB9M – RS-232

 

Connector

Cannon 9 (DB9M)

Pinout

Standard IBM PC – DB9M (RxD, TxD, RTS, CTS, GND)

Usage

Serial setup, 9600 8N1

Max. distance

2 m

DI – Inputs (Dry contact inputs)

Port

I1 – l24

Type

24× Digital Input (for a voltage-free contact, such as a NO/NC relay contact, Dry Contact)

Sensitivity

1 (On) = 0-500 

Ω

 (Up to 12 V can appear at the socket against GND)

Pulse counter

24× 32-bit, min. pulse width 20 ms. Counter value is retained even after power disconnection.

Max. distance

Up to 50 m

LED 

Power (RJ45)

Green – power OK

Link & Activity (RJ45)

Green – physical connection established, Yellow – flashes, communication taking place

Alarm & RS-232 Setup 

Red – flashing – device in RS-232 Setup mode

Alarm

On

Setup

Flashing

Parameters 

Power 1

9–30 V / consumption  approx.  250 mA / 12 V  DC 

Power 2 (PoE)

PoE (IEEE 802.3af) 

Power 3 (-48V)

-48 V DC Telco standard (-30 V to -60 V DC) 

Power connector 1

1× barrel jack (2.5 mm, outer diameter 6.3 mm), + inside
2× terminal block (U+ / GND)

Temperature ranges

Operation: -30 to +65 °C (+14 to +150 °F)
Storage: -30 to +85 °C (-22 to +167 °F)

Dimensions/mass

179 × 46 × 116mm / 400 g

-48V

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

NO3

NO4

-48V

+U

IN13

IN14

IN15

IN16

IN20

IN17

IN21

IN18

IN22

IN19

IN23

IN24

COM3

COM4

NC3

NC4

GND

+U

GND

IN1

GND

IN2

GND

IN3

GND

IN4

GND

IN8

GND

IN5

GND

IN9

GND

IN6

GND

IN10

GND

IN7

GND

IN11

IN12

GND

NO1

COM1

NC1

NO2

COM2

NC2

IN1

IN13

IN2

IN14

IN3

IN15

IN4

IN16

IN5

IN17

IN6

IN18

IN7

IN19

IN8

IN20

IN9

IN21

IN10

IN22

IN11

IN23

IN12

IN24

OUT1

OUT3

Status

Link

OUT2

OUT4

Alarm

Pow

er

SECURITY

 

SE

TUP

ON

100 mm

45,5 mm

108 mm

116 mm

171 mm

179 mm

8 mm

ø4,8 mm (2×)

2   1

Summary of Contents for Damocles2 1208

Page 1: ...Damocles2 User manual...

Page 2: ...epublic and the European Union The device has been tested and is supplied in working order To keep the de vice in this condition it is necessary to adhere to the following safety and maintenance instr...

Page 3: ...IN1 IN1 NC1 COM1 NO1 NO2 NC2 COM2 Outputs Setup Safe Ethernet GND U Power 9 30V Damocles2 1208 SETUP SAFE IN1 GND IN2 IN3 GND IN4 IN5 GND IN6 IN7 GND IN8 IN9 GND IN10 IN11 GND IN12 GND GND GND GND GN...

Page 4: ...e upload Yes Yes Yes Modbus TCP Yes Yes Yes HWg PUSH SensDesk protocol Yes Yes Yes NotGSM SMS GW protocol Yes Yes Yes Box 2 Box 4 SNMP protocol for VDO Yes Yes Yes Box 2 Box 16 HTTP protocol for VDO Y...

Page 5: ...de of the safe range flashing means TCP or Serial Setup mode DIP1 DIP2 switches DIP1 activates serial setup mode restores factory defaults To restore factory defaults quickly toggle the switch 3 withi...

Page 6: ...e of the device Enter the device IP address in a web browser Click the IP address in UDP Config Click the underlined IP address in UDP SETUP The WWW page displays current status of the device and its...

Page 7: ...l General Setup Security SNMP Modbus E mail GSM Log Time Portal Inputs Outputs Virtual Outputs System Overview of current readings IP address DNS IP filter security username password HTTPS certificate...

Page 8: ...evice 2 HTTPS certificates 3 Note For a detailed description see the detailed web interface description 2nd half of the manual Changes SNMP protocol versions 1 SNMP 5 destinations for SNMP Traps 2 Not...

Page 9: ...network settings 3 SMTP server and port 4 Authentication enabled correct username and password 5 Spam filter for your mailbox is disabled E mail This text is inserted at the beginning of the e mail s...

Page 10: ...r whenever a change in a sensor value exceeds the configured AutoPush value Connection parameters for the www SensDesk com portal are pre filled AutoPush configuration Whenever an input state changes...

Page 11: ...put 1 1 2 3 Pulse Timer When set the output is activated only for a specified duration Pulse Timer 0 disables this function For details see the WEB interface description Output mode A Manual DO can be...

Page 12: ...ry 60s For more information see Web interface Virtual Outputs System Restores factory defaults 1 Uploads new firmware from the PC 2 Configuration Download download the configuration from the device to...

Page 13: ...tacts read as 1 On resistance against the Common pin must not exceed 500 Specifications Maximum wiring length 50m Supported sensors Any contact without external voltage dry contact Alarm settings for...

Page 14: ...or TCP Setup Ability to restore factory defaults Detailed program description as well as an instructional video clip are available on the CD supplied with the device or at our website http www hw grou...

Page 15: ...be used for example to read energy consumption meters with a pulse output S0 Counters are incremented whenever the input is closed The pulse must be longer than 20 ms to be registered Outputs Displays...

Page 16: ...p events E mailing SMTP Logging of values with timestamps IPV6 This block groups options for operation in networks that support IPv6 Enable IPV6 Enables IPv6 support Autoconfig IP parameters Enables a...

Page 17: ...fy the restrictions resulting from the respective security settings No restrictions default HW protection DIP On User Password IP Access filter SNMP Communities Read only Read Outputs Read Write HTTP...

Page 18: ...ts feature Toggle DIP1 several times during the first 5 seconds after powering up the device HTTPS Server Certificate files Used to manage certificates needed for the HTTPS server Allows you to upload...

Page 19: ...e communication Available options are DES and AES Privacy Password Password key for encrypting the communication MIB II System Group User defined data in the standard SNMP header SysContact Contact in...

Page 20: ...Name Username for authentication with the SMTP server Password Password for authentication with the SMTP server E mail Subject Text Subject of the e mails sent followed by the default e mail text see...

Page 21: ...53 BinOut 3 OFF Manual 154 BinOut 4 OFF Manual 155 BinOut 5 OFF Manual 156 BinOut 6 OFF Manual 157 BinOut 7 OFF Manual 158 BinOut 8 OFF Manual 1151 VirtBinOut 1 OFF Manual 1152 VirtBinOut 2 OFF Manual...

Page 22: ...its in your programs section http hw group us cs podpora kba004 pouziti damocles2 ve vasich programech Note Any changes must be confirmed by clicking the Apply Changes button A successful change is in...

Page 23: ...ports when there is no active communication Note The clock does not run when the device is powered off The device contains no battery After a power failure the time will be synchronized with the SNTP...

Page 24: ...ining time before the next standard data upload Current Log Timer Indicates the remaining time before the next caching of data Current Check Timer Indicates the time remaining until the next Check Pus...

Page 25: ...sending data to the MQTT broker Topic Prefix Name MQTT Topic adress prefix Inputs Topic Name Corresponds to the input name at the Inputs tab ID Corresponds to the input ID at the Inputs tab Publish En...

Page 26: ...beginning and alarm end Out of Safe Range Response to the Alarm state activation deactivation for dry contact inputs SNMP Trap Enables sending a SNMP trap upon alarm activation deactivation E mail Ena...

Page 27: ...fter confirming with Apply Changes Local Condition Output is controlled using a condition and a sensor The output state is read only for M2M protocols output cannot be controlled The control is linked...

Page 28: ...t the Outputs tab at the remote side Username Password If the remote side uses SW protection against unauthorized use enter the Read Write or the Read Outputs password System Communication monitor Mon...

Page 29: ...application runs in the background NTservice Data is retrieved from the devices over http or e mail Data can be exported over XML or automatically stored to MS Excel HWg Trigger Windows application f...

Page 30: ...0 27 Server room 366985520 France Rue des Champolains 29 Auxerre 48 2 RH 10 30 26 Showroom 302871441 Italy Via Marco Claudio 778 Terni 0 none unit 10 30 25 Storage 652924144 Sweden Nyborgsgatan Arvids...

Page 31: ...n after power disconnection Max distance Up to 50m LED Power RJ45 Green power OK Link Activity RJ45 Green physical connection established Yellow flashes communication taking place Input Output Status...

Page 32: ...y RJ45 Green physical connection established Yellow flashes communication taking place Input Output Status Green input Yellow output Alarm On Setup Flashing Parameters Power 9 30V 1 7W DC Power connec...

Page 33: ...Dry Contact Sensitivity 1 On 0 500 Up to 12V can appear at the socket against GND Pulse counter 24 32 bit min pulse width 20ms Counter value is retained even after power disconnection Max distance Up...

Page 34: ...dnotkach poseidon2 a damocles2 HTTPS in Damocles2 and Poseidon2 http hw group us cs podpora kba003 https v jednotkach poseidon2 a damocles2 Formats and interfaces Formats and interfaces Poseidon2 4002...

Page 35: ...HW group s r o Formansk 296 Prague 149 00 Czech Republic Phone 420 222 511 918 Fax 420 222 513 833 www HW group com...

Reviews: