HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
P/N 3110238_B
2-1
Smart Exchange Food Lockers
MAIN DISCONNECT SWITCH
Each refrigerated module is equipped with a
dedicated main disconnect switch/breaker. The
switch will interrupt power to the entire refrigerated
module. The switch is located on the right side
of the refrigerated module control panels (when
facing them), and on the inside electrical panel
behind the display screen of the kiosk. The
image below shows the disconnect switches.
Electrical Connection
(rear of refrigerated module)
ETHERNET
Connectivity to the Internet is provided by the
customer building or using a 4G cellular card.
Please see Steps in this Section to connect
Ethernet to control kiosk via the Sophos device.
For software and software component remote
troubleshooting, call 1-866-386-9398.
CONDENSING UNIT WITH ELECTRICAL PANEL LOWERED FOR MAINTENANCE
EVAPORATOR FAN
TXV
DISCONNECT
SWITCH
ES
COMPRESSOR
CONDENSER COIL &
FAN ASSY
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
LIQUID RECEIVER
HEAD PRESSURE
VALVE
ACCUMULATOR
COMPRESSOR CRANKCASE HEATER
THERMOSTAT (LOW TEMP CASE ONLY)
HEATER LIMIT THERMOSTAT
EVAPORATOR COIL
Disconnect Switches
FIELD CONNECTIONS
Proper Field Wiring and Grounding Required!
Failure to follow code could result in death or serious
injury. All field wiring MUST be performed by qualified
personnel. Improperly installed and grounded field
wiring poses FIRE and ELECTROCUTION hazards.
To avoid these hazards, you MUST follow require-
ments for field wiring installation and grounding as
described in NEC and your local/state electrical codes.
SHEET 6 OF 6
84.07
1.82
ELECTRICAL
The locker assembly is electronically controlled
by the CoreLink Controller.
Refer to the serial
plate or data sheets for electrical information.
Field wiring is done at the junction box located at
the rear of each refrigerated module.
FIELD WIRING
Field wiring must be sized for component amperes
stamped on the serial plate. Actual ampere
draw may be less than specified.
It is the responsibility of the installing contractor(s)
to make connections and ensure local codes are
followed. See wiring diagram and circuit re-
quirements for each refrigerated module before
making any electrical connections.
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES.
Electrical
Junction
1.8”
84”
Summary of Contents for Smart Exchange
Page 48: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 4 8 NOTES...
Page 56: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 8...
Page 58: ...P N 3110238_B U S Canada 1 800 922 1919 Mexico 01 800 890 2900 www hussmann com 5 10 NOTES...
Page 68: ...P N 3110238_B 8 4 APPENDIX Sensor Resistance Pressure Sensor SENSOR REISTANCE AND PRESSURE...