![Hussmann Freedom Line series Installation & Operation Manual Download Page 45](http://html1.mh-extra.com/html/hussmann/freedom-line-series/freedom-line-series_installation-and-operation-manual_2189217045.webp)
P/N 0520677_W
3-3
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Freedom Line Reach-in
SEALING SPLASHGUARD TO FLOOR
i
f
required
by local sanitation codes, or if
desired by the customer, plastic splashguards
may be sealed to the floor using silicone type
sealer. The amount needed will depend on how
much the floor is out of level.
• Remove all dirt, wax and grease from the
area of the splashguard where adhesion will
be necessary. This is to ensure a good, secure
installation.
• Apply a good silicone type sealer along the
bottom of the splashguard. Sealant must be
removed and replaced when servicing.
o
pTional
s
tainless steel splashguards may be
sealed to the floor using a vinyl cove base trim.
The size of trim needed will depend on how
much the floor is out of level.
To install the trim to the splashguard:
• Remove all dirt, wax and grease from the
area of the splashguard where adhesion will be
necessary. This is to ensure a good and secure
installation.
• Apply a good contact cement to the cove
trim and allow proper drying time according
to the directions supplied with the cement.
• Install the trim to the splashguard so that it
is lying flush with the floor.
D
o
not
seal
the
trim
to
the
floor
.
•
If required by local health codes
Cove Trim
may be sealed to the floor using a silicone type
sealer. Sealant must be removed and replaced
when servicing.
Splashguard
Silicone-type
Sealer
Splashguard
Cement
Cove Trim